background image

CCEI 

Limpido EZ

®

  

Duo

 

v1.0 

 

Page 10 

 

Overproduction 

 
This  alert  is  generally  caused  by  an  excessive 
amount  of  salt  in  the  pool  or  an  increase  of  the 
water temperature. 
To  avoid  having  an  excess  current  damage  the 
cell  and  the  control  relays,  the  device  cuts  off 
production  as  soon  as  such  a  situation  is 
detected. 
Overproduction occurs mostly at the moment salt 
is  added  to  the  pool  when  the  device  is  started 
before the salt is completely diluted. 
Check the salt ratio ; if the ratio exceeds 5g/l, the 
water should be drained and then the pool should 
be filled until a salt ratio less than or equal to 5g/l 
is obtained. 

 

Underproduction 

 
To  avoid  damaging  the  cell  plates  during  an 
operation  with  not  enough  salt,  the  device  is 
equipped with a detection device which stops the 
treatment as soon as there is a lack of salt.  

 
Check the salt ratio ; if the ratio is less than 
2.5g/l  (2500ppm), 

salt  has  to  be  added  and 

production may be restarted only when the salt is 
completely diluted. 
If  the  salt  ratio  is  correct,  then  either  the  cell  is 
scaled  or  it  is  worn  out.  Consequently,  the  cell 
should be dismounted and the state of the plates 
checked. If necessary, descale it (cf 

Cleaning the 

cell

). 

 
In 

Automatic mode

 (thermoregulated) and if 

Limpido EZ

®

 Duo

 could not produce throughout the 

required  time  despite  forced  operation,  the  device  signals  underproduction  by  flashing  the 

 

indicator light. In this case, the daily filtration time should be increased. 
 

 
Since  water  conductivity  decreases  with  temperature,  the  chlorine  production  decreases  when  the 
water cools. This phenomenon is taken advantage of to limit production in winter when the amount of 
chlorine needed to disinfect becomes very low. 
 

PH REGULATION 

PH INDICATOR 

Indicator light 

 

When the left indicator light is lit, it 
means  that  the  water’s  pH  is  less 
than  the  setpoint  value :  The 
dosing pump is stopped.  

Indicator light   

When  the  central  indicator  light  is 
lit,  the  water’s  pH  is  equal  to  the 
setpoint  value :  The  dosing  pump 
is stopped. 
 

Indicator light   

When the right indicator light is lit, 
the  water’s  pH  is  greater  than  the 
setpoint  value :  The  dosing  pump 
is running. 
 

PH SETPOINT 

The rotary switch allows selecting one of the four setpoint values :  
7.0 / 7.2 / 7.4 / 7.6 
This  value  defines  the  threshold  above  which  the  pump  starts  running  to  add  acid  to  the 
pool. 

 

OVERDOSE INDICATOR LIGHT 

To  reduce  the  risk  of  overdose  caused  by  a  possible  pH  measurement  error, 

Limpido  EZ

®

 

Duo

 inhibits the pump from running if the pH is not corrected within 3h. Thus, the maximum 

volume injected in 24h is limited to 2.7 litres. 

To  cancel  an  overproduction  fault,  it  is  necessary  to  stop  and  then 
restart the device. 

Содержание Limpido EZ DUO 60

Страница 1: ...Installation 4 Start up 6 Calibration 7 Operation 8 Maintenance 11 Reference Version Date MPET0219 v1 0 19 02 2014 Technical Manual v1 0 Warning Carefully read this manual before installing starting o...

Страница 2: ...dissolves immediately in the water producing hydrochlorous acid HClO This powerful disinfectant destroys bacteria and algae before it retransforms into salt The amount of chlorine needed to disinfect...

Страница 3: ...in the pH of the water between 7 0 and 7 6 For information the table to the right allows determining the required production time versus the basin volume the pH for a water temperature of 25 C Since t...

Страница 4: ...he detector must be pointing in the direction of the water s flow COVER CONTACT This input must be connected to the drycontact of the cover s travel limit switch or the pool s flap Thecontact must be...

Страница 5: ...reasons the Limpido EZ Duo box must be installed more than 3 50 m from the pool edge The box must be placed on a flat stable support It must be supplied with a single phase 230V 50Hz power supply and...

Страница 6: ...chlorine from the degradation that the sun s ultraviolet UV radiation subjects it to On the other hand this cyanuric acid is not consumed and inexorably accumulates in pools treated with chlorine pebb...

Страница 7: ...he central indicator light green turns on Turn to the minus sign if the left indicator light red is lit Turn to the plus sign if the right indicator light red is lit When the central indicator light g...

Страница 8: ...CHOICE In Automatic mode pressing and holding down the key for 3 seconds allows changing the adapted thermoregulation curve The indicator light corresponding to the active curve flashes To select the...

Страница 9: ...dic flash Water temperature too low to produce 10 C 5 periodic flashes Filtration insufficient Forced filtration Permanently flashing Temperature measurement error POLARITY INDICATOR The cell is clean...

Страница 10: ...if Limpido EZ Duo could not produce throughout the required time despite forced operation the device signals underproduction by flashing the indicator light In this case the daily filtration time shou...

Страница 11: ...to keep the cell from operating in a water with too low a salt content 2g l In case a tarpaulin or a cover is used the chlorine is protected from UV radiation To prevent an over chlorination the prod...

Страница 12: ...laration The Bleu Electrique SAS Company FR 47 403 521 693 declares that the LIMPIDO EZ Duo product satisfies the safety and electromagnetic compatibility requirements of the European directives 2006...