1.
GENERAL
A.
This section contains testing and fault isolation for the Liquid
Soap Dispenser.
B.
The procedures given below must be completed if a failure is found
with Liquid Soap Dispenser during use, or to make sure that the unit
is serviceable before it is put into or put back into service.
C.
Carry out all procedures in a clean area to avoid scratches or other
damages of any part.
D.
Numbers in parenthesis following item names in the procedures refer
to the figures and item numbers in page-block 10001, ILLUSTRATED
PARTS LIST.
E.
Make a visual inspection of the Liquid Soap Dispenser as detailed in
page-block 5001, CHECK.
2.
LIST OF POSSIBLE DEFECTS
NOTE: Ensure that soap container is filled. If the unit does not
discharge any soap and defects listed below are not
determinable, check that the unit contains the recommended soap
(Refer to chapter SERVICING).
FAULT PROBABLE
CAUSE
CORRECTION
ACTION
NO, OR INSUFFICIENT
SOAP DISCHARGE
A.
CONNECTION BETWEEN
PISTON ASSY AND TUBE
IS LOOSE
B.
CONNECTION BETWEEN
PISTON ASSY AND TUBE
IS DEFECTIVE
C.
PVC-TUBE TOO SHORT
D. PVC-TUBE TOO LONG
(REF. IPL, FIG.
1A-20 TO 1M-20)
- CONNECT TUBE WITH
THE PISTON ASSY
- REPLACE PVC-TUBE
- REPLACE PVC-TUBE
- CUT PVC-TUBE TO OR
INSTALL PVC-TUBE
WITH CORRECT LENGTH
AND NOTCH AT THE
LOWER END