C
OMPONENT
M
AINTENANCE
M
ANUAL
S
OAP
D
ISPENSERS
S
EIFENSPENDER
B82X
S
ERIES
No.: 25-40-01
Issue: D
Date: May 02/2022
25-40-01
May 02/2022
(3)
Installation of Unit PN B825 Series (Ref. Fig. 13003)
See installation of Unit PN B828 Series below.
(4)
Installation of Unit PN B828 Series (Ref. Fig. 13003)
WARNING:
IN ORDER TO GUARANTEE MAXIMUM PERFORMANCE OF
LIQUID SOAP DISPENSER LIQUID SOAP MUST HAVE A
VISCOSITY < 30 MPA/S, NACL-SHARE < 1 % AND BE
FREE OF ALCOHOL AND AROMATIC COMPOUNDS. WE
RECOMMEND TO USE ONLY THE ORIGINAL SOAP APPROVED
BY CBS - CARSTEN DAUS GMBH.
(a)
Install metal washer and rubber washer onto shank.
(b)
Insert the piston assy together with upper part of the
shank and PVC-tube into the mounting hole of the cabinet.
NOTE:
Ensure that the outlet of the piston extends over
the sink and that it remains in position during
further installation. If shank is to be installed
without piston and spout, ensure that the spring
in the lock ring is lined up with the expected
outlet direction.
(c)
Install the tooth lock washer and the retaining nut
onto the shank.
CAUTION: TO PREVENT DAMAGE TO SHANK ASSY, DURING FASTENING
RETAINING NUT, USE NOT TOO MUCH POWER. TORQUE
VALUE IS 15,00 NM (11.06 lbf.ft.).
(d)
Tighten up retaining nut hand tight.
(e)
Attach the silicon-tube together with sleeves and
flexible metal pipe with the clamp "A" to the shank.
(f)
Install the holder into the cabinet.
NOTE:
If holder is to be installed for the first time,
mounting holes with a diameter of 5 mm (0.19 in.)
must be drilled. Use appropriate screws taking
into consideration the material and thickness of
the wall.
PAGE 13006