MISC
TX-Power
In case of a short distance between the two AirLasers it is necessary to reduce the optical transmitter power,
to prevent overloading the receiver. Whether a receiver is overloaded or not, you can recognize by the APD-
factor (see status site).
The single beam device has two power levels, the four-beam device has four power levels. To the four-beam
device, the stages in which all four lasers are in operation, are preferred. This increases the susceptibility to
atmospheric influences (heat shimmer, rain, snow, etc.).
With activated Automatic Transmit Power Control (ATPC) the transmission power is automatically increased
to the maximum, if the received power of the remote falls below -25dBm. After reaching -12dBm receive
power, the preselected reduction is activated again.
TX Reduction
Leistung in %
IP1000plus/100
IP1000plus/800
0dB
100
1 x 10mW
4 x 10mW
3dB
50
-
2 x 10mW
6dB
25
1 x 2,5mW
4 x 2,5mW
6dB with ATPC
25/100
1 x 2,5mW / 1 x 10mW
4 x 2,5mW / 4 x 10mW
9dB
12,5
-
2 x 2,5mW
9dB with ATPC
12,5/100
-
2 x 2,5mW / 4 x 10mW
LASER off
0
0
0
Display Mode
The AirLaser IP1000plus has an LED display on the device, which serves to align and control the system. If
the display is not needed, it can be turned off on the device or the management. Thus, the device will be less
noticeable especially at night.
26
Содержание AirLaser IP100plus
Страница 1: ...1 Manual Version 2 13e Date 12 2019 for firmware 2 13 ...
Страница 16: ...Now the IP access to the terminal is configured and you can log into the webmanagement 16 ...
Страница 29: ...For evaluation please send the file by email to the address lists of the CBL customer service staff 29 ...
Страница 40: ...40 ...
Страница 48: ...Appendix D Expected Receiving Level 48 ...
Страница 49: ...49 ...