Resulting port status:
active
Port is currently being used for data transmission.
standby
(only controlled ports)
The port is for data transmission available, but not used, because another path is already
active.
blocked
(only controlled ports)
The data transfer is interrupted at this port through the management because, for example, the
switchback delay is not yet fully elapsed or a reflection is detected.
down
The port is not available for data transmission. The cause can be seen from the bad messages.
System Temperature Temperature inside the unit in the area of the optical receiver.
Screen Temperature Temperature of the heated front screen.
APD-Factor
The APD-Factor is a measure for the gain of the optical receiver.
Input Power
Status of both PoE input controller.
3.3V-Voltage
Internal 3.3-volt operating voltage.
Defroster
Status of the heated front screen.
on
Heating is on.
off
Heating is off
APD-Voltage
BIAS voltage of the APD receiver photo diode.
F1 RX-Level
Receive level at fibre port F1 (optional).