FA-20 SMS commands:
If the FA-20 receives a text SMS with the right password (typically
NNNN
) then the FA-20 will send
text SMS return to the sender with the following content:
Service SMS from FA-20, without option module:
FeltS: -063 dBm
Field strength in dBm: OK signal from -50 to -90dBm.
FA-20: 20090020
FA-20’s serial no.
Log T: 015
D: 28
Time between 2 loggings.
D: 28
means that driver no. 28 is chosen.
Multi: 06067774
Serial no. read from meter connected to MULTI port.
Mbus1:
Serial no. read from meter connected to M-bus port 1.
Mbus2:
Serial no. read from meter connected to M-bus port 2.
Puls1: 00000001
Pulse counter stand for pulse input no. 1.
Puls2: 00000001
Pulse counter stand for pulse input no. 2.
FA-IP:
IP configuration for GPRS, if loaded from the main station.
Tlf.1: DDDDDDDDDDDDDDDDDDDD
Telephone no. field 1 of 5 in FA-20.
Etc.
Etc.
Tlf.5: DDDDDDDDDDDDDDDDDDDD
Telephone no. field 5 of 5 in FA-20.
Service SMS from FA-20 with option module 1:
FeltS: -079 dBm
Field strength in dBm: OK signal from -50 to -90dBm.
FA-20: 99990000
FA-20’s serial no.
Log T: 000
D: 29
Time between to loggings.
D: 29
means that chosen driver is no. 29.
Multi: 08640751
Serial no. read from meter connected to MULTI port.
Mbus1: 06057654
Serial no. read from meter connected to M-bus port 1.
Mbus2: 00341449
Serial no. read from meter connected to M-bus port 2.
Puls1: 00010000
Pulse counter stand for pulse input no. 1.
Puls2: 00002000
Pulse counter stand for pulse input no. 2.
In 1: OFF 2: OFF
Signal on digital input no. 1 (on/off) and no.
2 (on/off)
In 3: OFF 4: OFF
Signal on digital input no. 3 (on/off) and no. 4 (on/off)
Out 1: OFF 2: OFF
Relay output no. 1 (on/off) and no. 2 (on/off)
mA 1: 00,0 2: 00,0
Signal on analog input no. 1 (0-20mA) and no. 2 (0-20mA)
FA-IP:
IP configuration for GPRS, if loaded from the main station
.
Tlf.1: DDDDDDDDDDDDDDDDDDDD
Telephone no. field 1 of 5 in FA-20.
Etc.
Etc.
Tlf.5: DDDDDDDDDDDDDDDDDDDD
Telephone no. field 5 of 5 in FA-20.
Service SMS from FA-20 with option module 2:
FeltS: -079 dBm
Field strength in dBm: OK signal from -50 to -90dBm.
FA-20: 99990000
FA-20’s serial no.
Log T: 000 D: 29
Time between 2 loggings. ”D: 28” means that chosen driver is no. 28
Multi: 08640751
Serial no. read from meter connected Multi port.
Mbus1: 06057654
Serial no. read from meter connected M-bus port 1.
Mbus2: 00341449
Serial no. read from meter connected M-bus port 2.
Puls1: 00010000
Pulse counter stand for pulse input no. 1.
Puls2: 00002000
Pulse counter stand for pulse input no. 2.
Puls3: 00000300
Pulse counter stand for pulse input no. 3.
Puls4: 00000040
Pulse counter stand for pulse input no. 4.
Puls5: 00000005
Pulse counter stand for pulse input no. 5.
Puls6: 00600000
Pulse counter stand for pulse input no. 6.
Out 1: OFF 2: OFF
Relay output no. 1 (on/off) and no. 2 (on/off)
mA 1: 00,0 2: 00,0
Signal on analog input no. 1 (0-20mA) and no. 2 (0-20mA)
FA-IP:
IP configuration to GPRS, if loaded from the main station.
Tlf.1: DDDDDDDDDDDDDDDDDDDD
Telephone no. field 1 of 5 in FA-20.
Etc.
Etc.
Tlf.5: DDDDDDDDDDDDDDDDDDDD
Telephone no. field 5 of 5 in FA-20.