18
To calculate the quantity of liquid to be sprayed per hectare, see
the following formula:
D = Q x 600 / L x V
where: D = Quantity to spray in l/hectare
Q = Overall flow rate of nozzles in l/min
L = Operating working width
V = Speed
That is:
Overall nozzle flow rate
x 600
Operating width
x speed
= litres of liquid per hectare
Calculation of liquid quantity in full field distribution
Round hole nozzle flow rate table
Flow rate in l/min
Fan hole nozzle flow rate table
Flow rate in l/min
Hole
mm
Ø 1.5
4.20
5.00
6.60
Ø 2.0
7.00
8.80
11.60
Ø 2.5
9.95
13.00
16.40
10 bar
15 bar
25 bar
Hole
mm
Ø 1.2
1.60
3.60
4.20
Ø 1.5
2.30
4.60
5.70
10 bar
15 bar
25 bar