D E S C R I P T I O N O F C O N T R O L - B O A R D E Q 2 1 2
F1 = fuse power 230V. 5 A.
L1 = green led light on signaling of presence of the tension of net to 220V.
L2 = red led light on, limit switch opens (l.s.a.) active.
L3 = red led light on, limit switch closes (l.s.a.) active.
L4 = yellow led light on, activated stop.
L5 = yellow led light on, photocell 1 summoned.
L6 = red led light on, active start (or opens)
L7 = red led light on, pedestrian activated (or closes)
L8 = red led flashing with summoned reverser. red led light on 2,5 sec. before
the arrival of the gate against the final wisecrack.
L9 = yellow led light on photocell 2 summoned.
P1 = trimmer setting of the pushing power of the motor, min. 110V. max.
230V. c.a.
P2 = trimmer setting time of work from 0 to 90 sec.
P3 = trimmer setting time of break from 0 to 125 sec.
P4 = trimmer setting sensibility to the obstacle during the normal speed.
P5 = trimmer setting to the obstacle in the space of deceleration.
J1 = connection for radio receiver (12 V. d.c.)
J2 = sprout motor inserted with J2 closed (1). Sprout motor excluded with J2
opened (0).
J3 = Maximum power to the motor in closing in the last 2 sec. inserted with
closed J3 (1) - excluded with opened J3 (0).
J4 = Survey amperhometric in deceleration activates with closed J4 - excluded
with opened J4
E L E C T R I C A L C O N N E C T I O N O N T H E T E R M I N A L B O A R D M 1
M1-M2 feeding singlephase 220 V; 1 phase 2 neutral.
G Mass Earth
G Mass Earth
M3-M4-M5 exit for the connection of the motor max. 300watt 230V. closing to
the clamp n° 5 (condenser), opening to the clamp n° 3 (condenser)
and common to the clamp n° 4;
M6-M7 exit for blinker max. 40 watts 230 Vs a.c.; it is activated as from
selection DIP 4 in opening in closing;
E L E C T R I C A L C O N N E C T I O N O N T H E T E R M I N A L B O A R D M 2
M10 input common limit switch
M11 input limit switch closing N.C.
M12 input limit switch opening N.C
M13 Photocell 1 input , N.C.; it is activated only during the closing
(it arrests and it reopens).
M14 input of stop N.C. after having activated the stop, another start makes to
leave again the motion in the inverse sense
M15 input start N.O.
M16 input of pedestrian. The gate opens for 11 sec. and it closes again for
the whole time of job regulated with P2
M17 input common of the M13-M14-M15-M16
N.B. The inputs N.C. not used must obligatorily be short-circuits
toward the commune of the inputs.
E L E C T R I C A L C O N N E C T I O N O N T H E T E R M I N A L B O A R D M 3
M8-M9 clean contact max. 230 V. 4 amps. N.O. for connection light of
courtesy, the beginning of every manoeuvre is activated and it is
disarmed after 3 minutes
E L E C T R I C A L C O N N E C T I O N O N T H E T E R M I N A L B O A R D M 4
M18-M19 output for electrolock 12V c.a. – max. 15W, it is activated only In
opening and for the duration of 4 seconds
M19-M20 output feeding to 24V c.as. for receiver and photocells, max. 400 mA.
E L E C T R I C A L C O N N E C T I O N O N T H E T E R M I N A L B O A R D M 5
M21-M22 safety contact N.C. The opening of the contact removes feeding to
the spools of the relé for the time that the contact stays open.
E L E C T R I C A L C O N N E C T I O N O N T H E T E R M I N A L B O A R D M 6
M23-M24 output clean contact of the 2° channel radio.
M25-M26 input N.C. safety photocell 2. The operation depends on the
formulation of the dip-switch 3.
M26-M27 input spar for receiver: stocking of mass to 26, soul spar to 27.
CONNECTOR J1-RX = connection radioreceiver.
TRANSFORMER L.16 PRIMARY 220-380V. 1
ST
SEC 12V. MAX A 0.30 (300 mA) FOR LOGIC.
2
ND
SEC 12-0-12V. MAX A 0.35 (350 mA) FOR OPTIONALS SERVICES. CONFORM TO CEE DIRECTIVE EMC 89/336/CEE
Directive LVD 73/23/EEC and following changes - EMC 89/336/EEC and following changes and to the Harmonized Norms
EN 60335-1 EN 61000-6-1 EN 61000-6-2 EN 61000-6-3 EN 61000-6-4.