background image

 

Page 8 of 14                                                                                 EQ2006  R.1.5                                                                         Rev. 02 dated 09/11/2007 

 
 

At the end of the stroke in opening of the motor 2 the state of the 
leds is that represented to the left side 
 
 

 

Hold pressed the key PS1 to start the motor 2 in closing; release the key to stop the 
leaf in the point in which you desire to fix the leaf delay in closing
WARNING! If you don’t want to plan any delay shutter in closing send a short impulse 
with the key PS1 to pass over  the following point   
 
 
 
Hold pressed Hold pressed the key PS1 to plan the time of work in closing for motor 
2

WARNING! If you want  to plan the final portion of the stroke in deceleration, release the 
key PS1 in the point in which you desire to continue with the low speed.   
If you want to effect the whole stroke with normal speed, maintain pressed PS1 and  
release it just  at the end of the closing (when limit switch is working FCC 2). 
 
 
Hold pressed the key PS1 to plan the last portion of opening for motor 2 in deceleration  
and release it  just at the end of the opening (when limit switch is working FCC 2). 
If the leaf is already completely closed because abdicates the deceleration, and if the 
arrest has not happened with the limit switch FCC 2, send a short impulse with the key 
PS1 to pass over the following point. 
 

 

At the end of the stroke in closing of the motor 2 the state of the 
leds is that represented to the left side 
 
 

Hold pressed Hold pressed the key PS1 to plan the time of work in closing for motor 
1

WARNING! If you want  to plan the final portion of the stroke in deceleration, release the 
key PS1 in the point in which you desire to continue with the low speed.   
If you want to effect the whole stroke with normal speed, maintain pressed PS1 and  
release it just  at the end of the closing (when limit switch is working FCC 1). 
 
Hold pressed the key PS1 to plan the last portion of opening for motor 1 in deceleration 
and release it  just at the end of the closing (when limit switch is working FCC 1). 
If the leaf is already completely closed  because abdicates the deceleration, and if the 
arrest has not happened with the limit switch FCC 1, send a short impulse with the key 
PS1 to pass over the following point 
 
 

At the end of the stroke in closing of the motor 1 so the complete 
gate the state of the leds is that represented to the left side 
 
 

 

 
Send a short impulse with the key PS2; 
the led REV 1 flash asking the confirmation of the time of planned work. 
WARNING! If you want to repeat the setting of the time of work to this point press the key 
PS1 to go to the beginning conditions. 
 
 
 
To confirm, send a short impulse with the key PS2; the 3 leds switch on green fixed light 
for 2 seconds pointing out the memorization of the time of work 
 
 
 
 

 

Subsequently the control panel will be ready again in the initial  
planning  menu turning on fix red light the led REV 1. 
 

 

REV 1 

(red) 

 
 

REV 2 

 
 

SET 

REV 1 

(red) 

REV 2 

(green) 

SET 

REV 1 

(red) 

REV 2 

SET 

(green) 

REV 1 

(red) 

REV 2 

(green) 

SET 

(green) 

 

REV 1 

(red) 

 
 

REV 2 

 
 

SET 

REV 1 

(red) 

REV 2 

SET 

(green) 

REV 1 

(red) 

REV 2 

(green) 

SET 

(green) 

 

REV 1 

(red) 

 
 

REV 2 

 
 

SET 

REV 1 

(red) 

REV 2 

SET 

REV 1 

(green) 

REV 2 

(green) 

SET 

(green) 

 

REV 1 

(red) 

 
 

REV 2 

 
 

SET 

Содержание EQ2006

Страница 1: ...F DIP 2 ON S1 DIP 1 ON DIP 3 ON ON When the contact of the timer is released the gate close after the time selected SLOW DOWN MOTORS it is possible to set the slow down motor in opening and closing du...

Страница 2: ...common to the clamp 9 closing to the clamp 10 M6 11 12 Light of courtesy clean contact N O max 230V 4 Amp see S3 dip 8 M7 13 14 Output 12Vdc max 200 mA 14 15 Input N C SAFETY EDGE 1 In opening it arre...

Страница 3: ...o the intervention of the safety edge 1 The flashing led L2 points out the condition of triac TH1 pilot motor 1 in damage L3 SAFETY EDGE 2 it switch on to the intervention of the safety edge 2 The fla...

Страница 4: ...en the gate is closed and foto 1 obscurated the gate not open during the closing and foto 1 obscurated the gate stop and reopen when the foto1 is liberated in this operation is activated also the elec...

Страница 5: ...e memorization involves to repeat the procedure of the first setting because the times of work and the setting of the reverse changes S2 dip 9 according to the used motors ON two motors OFF one motor...

Страница 6: ...nal portion of the stroke in deceleration release the key PS1 in the point in which you desire to continue with the low speed If you want to effect the whole stroke with normal speed maintain pressed...

Страница 7: ...aintain pressed PS1 and release it just at the end of the opening when limit switch is working FCA 1 Hold pressed the key PS1 to plan the last portion of opening for motor 1 in deceleration and releas...

Страница 8: ...motor 1 WARNING If you want to plan the final portion of the stroke in deceleration release the key PS1 in the point in which you desire to continue with the low speed If you want to effect the whole...

Страница 9: ...TIME BRAK Inside the planning menu press the push button PS3 to go in the parameter Pedestrian time break The state of the leds represented to the left side points out that it is in the menu related t...

Страница 10: ...onnect the positive pole of the leds to the source of feeding and the negative pole of every leds to the clamp F of the relative terminal block Naturally the negative one of the source of feeding must...

Страница 11: ...celeration ON strength range high OFF strength range low respectively on motors 1 and 2 During the reverse intervention a short flash red is gotten on the led REV 1 if it intervenes on the motor 1 or...

Страница 12: ...the bridge The motors limit switches are missing of is not present the bridge among the input 20 21 23 24 and the commune Verify the limit switches of the motor or the presence of the bridge A key se...

Страница 13: ...th several wires and always separate the power from the low tension Connect wires to the control box from the bottom through pass cables only MAINTENANCE To ensure product efficiency it is essential t...

Страница 14: ...Page 14 of 14 EQ2006 R 1 5 Rev 02 dated 09 11 2007...

Отзывы: