SAFETY WARNINGS FOR INSTALLATION AND USE 
These warnings are an essential, integral part of the product and must be given to the user. They provide important indications on the installation, 
use and maintenance and must be read carefully. This form must be preserved and passed on to subsequent users of the system. The incorrect 
installation or improper use of the product may be dangerous. 

WARNINGS FOR THE INSTALLER 

 

The installation must be performed by professionally skilled personnel and in compliance with current local, state, national and European 
legislation. 

 

Before beginning the installation, check the integrity of the product. 

 

The laying of cables, electrical connections and adjustments must be workmanlike performed. 

 

The packing materials (cardboard, plastic, polystyrene, etc.) are a potential hazard and should be disposed of correctly and not left within reach 
of children. 

 

Do not install the product in potentially explosive environments or environments disturbed by electromagnetic fields. The presence of 
inflammable gases or fumes is a grave danger to safety. 

 

Set up a safety device for overvoltage, a disconnecting and/or differential switch suitable for the product and conforming to current standards. 

 

The control should be installed as near the gate as possible, 2) 

If this is not possible, you should: 

 

Use cables with proper sizes. 

 

NEVER use multiwire cable to connect either the motor or all the services (open, photocell, block, end-run), but ALWAYS SEPARATE 
THE POWER FROM THE LOW TENSION (controls and securities) by using more cables. 

 

The manufacturer declines any and all responsibility for product integrity, safety and operation in the event incompatible devices and/or 
components are installed. 

 

Solely original spare parts should be used for repairs and replacements. 

 

The installer must provide all the information relative to the operating, maintenance and use of the individual components and the complete 
system as specified in the MACHINE DIRECTIVE. 

 
 
 
 

 
 
 

 

Protect the upper side of the control box if it is installed 

outside in all weathers. 

 
 
 
 
 
 
 

 

Never use cable with several wires and always separate 

the power from the low tension. 

 
 
 
 
 
 
 
 
 
 
 

 

Connect wires to the control box from the bottom through 

pass-cables only. 

 
 
 
 

MAINTENANCE 

 

To ensure product efficiency, it is essential that professionally skilled personnel carry out maintenance within the times established by the 

installer, the manufacturer and by current legislation. 

 

All installation, maintenance, repairs and cleaning operations must be documented. This documentation must be preserved by the user, and 

made available to the personnel responsible for the control. 

WARNINGS FOR THE USER 

 

Read the instructions and enclosed documentation carefully. 

 

The product must be used for the express purpose for which it was designed. Any other use is considered improper and therefore hazardous. 

In addition, the information given in this document and in the enclosed documentation may be subject to modifications without prior notice. It is 
given as an indication only for product application. Casit  declines any responsibility for the above.  

 

Keep products, devices, documentation and anything else provided out of reach of children.  

 

In the event of maintenance, cleaning, breakdown or faulty operation of the product cut off the power and do not attempt to operate on the 

product except when indicated. Contact professional personnel, competent and suitable for the task. Failure to adhere to the above indications 
may be dangerous. 

WARRANTY LIMITS 

The warrantee is valid for 12 months from the date indicated in the sales document and its validity is limited to the original purchaser. It 

does not cover the following eventualities: negligence, incorrect or improper use of the product, use of accessories not conforming to the 

manufacturer's specifications, tampering by the customer or third parties, natural causes (lightning, floods, fire, etc.), riots, vandalism, 

modifications to the environmental conditions of the installation site. Nor does the warranty cover parts subject to wear (batteries, oil 

etc.). Products returned to Casit for repair shall only be accepted carriage paid. Casit shall return the repaired product to the sender 

carriage forward. Otherwise the goods will be refused on receipt. The purchase of the product implies the full acceptance of all the general 

terms of sale. Any dispute shall be submitted for judgement to the Court of Torino, Italy.  

Содержание EQ2006

Страница 1: ...F DIP 2 ON S1 DIP 1 ON DIP 3 ON ON When the contact of the timer is released the gate close after the time selected SLOW DOWN MOTORS it is possible to set the slow down motor in opening and closing du...

Страница 2: ...common to the clamp 9 closing to the clamp 10 M6 11 12 Light of courtesy clean contact N O max 230V 4 Amp see S3 dip 8 M7 13 14 Output 12Vdc max 200 mA 14 15 Input N C SAFETY EDGE 1 In opening it arre...

Страница 3: ...o the intervention of the safety edge 1 The flashing led L2 points out the condition of triac TH1 pilot motor 1 in damage L3 SAFETY EDGE 2 it switch on to the intervention of the safety edge 2 The fla...

Страница 4: ...en the gate is closed and foto 1 obscurated the gate not open during the closing and foto 1 obscurated the gate stop and reopen when the foto1 is liberated in this operation is activated also the elec...

Страница 5: ...e memorization involves to repeat the procedure of the first setting because the times of work and the setting of the reverse changes S2 dip 9 according to the used motors ON two motors OFF one motor...

Страница 6: ...nal portion of the stroke in deceleration release the key PS1 in the point in which you desire to continue with the low speed If you want to effect the whole stroke with normal speed maintain pressed...

Страница 7: ...aintain pressed PS1 and release it just at the end of the opening when limit switch is working FCA 1 Hold pressed the key PS1 to plan the last portion of opening for motor 1 in deceleration and releas...

Страница 8: ...motor 1 WARNING If you want to plan the final portion of the stroke in deceleration release the key PS1 in the point in which you desire to continue with the low speed If you want to effect the whole...

Страница 9: ...TIME BRAK Inside the planning menu press the push button PS3 to go in the parameter Pedestrian time break The state of the leds represented to the left side points out that it is in the menu related t...

Страница 10: ...onnect the positive pole of the leds to the source of feeding and the negative pole of every leds to the clamp F of the relative terminal block Naturally the negative one of the source of feeding must...

Страница 11: ...celeration ON strength range high OFF strength range low respectively on motors 1 and 2 During the reverse intervention a short flash red is gotten on the led REV 1 if it intervenes on the motor 1 or...

Страница 12: ...the bridge The motors limit switches are missing of is not present the bridge among the input 20 21 23 24 and the commune Verify the limit switches of the motor or the presence of the bridge A key se...

Страница 13: ...th several wires and always separate the power from the low tension Connect wires to the control box from the bottom through pass cables only MAINTENANCE To ensure product efficiency it is essential t...

Страница 14: ...Page 14 of 14 EQ2006 R 1 5 Rev 02 dated 09 11 2007...

Отзывы: