— 39 —
5-3-1. Jumper Settings
The SBC8360-4M is configured to match the needs of your application by proper jumper settings.
The following tables show the specification of the jumper settings. < : Default / “X”: Don’t Care >
Note:
All specification and quality of the system are assured by Casio as the QT-7300, any local
modification of the jumper setting by customer will not be applicable for Casio’s guarantee or
warranty.
5-3-2. CMOS Clear Jumper: JP4
JP4
Clear CMOS SRAM data
Short 1-2
Normal Operation
Open
5-3-3. Watchdog Trigger Mode Setting: JP7
The watchdog timer is an indispensable feature of the SBC8360-4M. It has a sensitive error detection
function and a report function. When the CPU processing comes to a halt, the watchdog can generate an
NMI or resets the CPU.
Watchdog Function
JP7
Activate NMI when Watchdog triggered
1-2
Reset system when Watchdog triggered
2-3
Disable
OPEN
5-3-4. LCD display Power Level Setting (V
DDM
of CN11 and CN6) : JP9
JP9
5V Panel Power Setting
1-2
3.3V Panel Power Setting
2-3