7 - MAINTENANCE
Transmission oil filter - Replace
WARNING
Chemical hazard!
When handling fuel, lubricants, and other service chemicals, follow the manufacturer's instructions.
Wear Personal Protective Equipment (PPE) as instructed. Do not smoke or use open flame. Collect
fluids in proper containers. Obey all local and environmental regulations when disposing of chemi-
cals.
Failure to comply could result in death or serious injury.
W0371A
WARNING
Pressurized fluid can penetrate the skin and cause severe injuries.
Keep hands and body away from any pressurized leak. DO NOT use your hand to check for leaks. Use
a piece of cardboard or paper. If fluid penetrates the skin, seek medical attention immediately.
Failure to comply could result in death or serious injury.
W0158A
Replace the transmission oil filter every 1500 hours or more frequently when operating conditions are severe.
Shorten the service intervals in severe applications which involve running the torque converter under high load for
more than 25% of operation time. Applications include basement digging or land clearing.
Prior operation:
Keep all non-authorized personnel clear of the area. Park the machine on level ground, in neutral with the parking
brake applied and the attachment lowered to the ground.
NOTE:
it is recommended to change the transmission oil when you replace the engine oil filter.
1. Lower the bucket/attachment to the ground and lock the
hydraulic functions of the machine.
2. Put the transport/service link into the locked service
position to avoid unexpected articulation movements.
Stop the engine.
3. Clean the area around the filter head.
4. Remove the filter.
5. Apply a film of clean
CASE AKCELA NEXPLORE™
FLUID
to the gasket of the new filter and install. Make
sure that the proper contact is made with the base.
6. Clean the transmission breather and reinstall. See the
transmission breather cleaning procedure. Refill with
clean
CASE AKCELA NEXPLORE™ FLUID
.
7. Check the oil level at the sight gauge.
8. Start the engine and check for oil leaks around the filter
and drain plug.
9. Bring the transmission oil up to working temperature,
and check the level again.
RCPH10WHL127AAH
1
7-108
Содержание 621G Stage IV
Страница 42: ...2 SAFETY INFORMATION Empty tool LEEN11T0024AA 20 2 22 ...
Страница 60: ...2 SAFETY INFORMATION 2 40 ...
Страница 137: ...3 CONTROLS AND INSTRUMENTS Inducement and validation re starts LEIL14WHL0394HA 2 3 77 ...
Страница 138: ...3 CONTROLS AND INSTRUMENTS Validation re start procedure LEIL15WHL0608HA 3 3 78 ...
Страница 150: ...3 CONTROLS AND INSTRUMENTS 3 90 ...
Страница 166: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 7 4 16 ...
Страница 168: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 9 4 18 ...
Страница 170: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 12 4 20 ...
Страница 208: ...6 WORKING OPERATIONS 6 18 ...
Страница 227: ...7 MAINTENANCE DEF AdBlue level faults failures and engine power loss levels LEIL15WHL0607HA 2 7 19 ...
Страница 228: ...7 MAINTENANCE DEF AdBlue quality faults failures and engine power loss levels LEIL15WHL0609HA 3 7 20 ...
Страница 229: ...7 MAINTENANCE DEF AdBlue technical faults LEIL14WHL0392HA 4 7 21 ...
Страница 370: ...7 MAINTENANCE 7 162 ...