7 - MAINTENANCE
Every 1000 hours
Pivot points - Grease
WARNING
Avoid injury! Always do the following before lubricating, maintaining, or servicing the machine.
1. Disengage all drives.
2. Engage parking brake.
3. Lower all attachments to the ground, or raise and engage all safety locks.
4. Shut off engine.
5. Remove key from key switch.
6. Switch off battery key, if installed.
7. Wait for all machine movement to stop.
Failure to comply could result in death or serious injury.
W0047A
Grease the fittings of the upper and lower chassis pivot points every 1000 hours or sooner if conditions so require.
Prior operation:
Keep all non-authorized personnel clear of the area. Park the machine on level ground, in neutral with the parking
brake applied and the attachment lowered to the ground.
Service specifications
Grease
T
UTELA
M
OLY
G
REASE
GR-75
LEIL16WHL0519FA
1
7-93
Содержание 621G Stage IV
Страница 42: ...2 SAFETY INFORMATION Empty tool LEEN11T0024AA 20 2 22 ...
Страница 60: ...2 SAFETY INFORMATION 2 40 ...
Страница 137: ...3 CONTROLS AND INSTRUMENTS Inducement and validation re starts LEIL14WHL0394HA 2 3 77 ...
Страница 138: ...3 CONTROLS AND INSTRUMENTS Validation re start procedure LEIL15WHL0608HA 3 3 78 ...
Страница 150: ...3 CONTROLS AND INSTRUMENTS 3 90 ...
Страница 166: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 7 4 16 ...
Страница 168: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 9 4 18 ...
Страница 170: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 12 4 20 ...
Страница 208: ...6 WORKING OPERATIONS 6 18 ...
Страница 227: ...7 MAINTENANCE DEF AdBlue level faults failures and engine power loss levels LEIL15WHL0607HA 2 7 19 ...
Страница 228: ...7 MAINTENANCE DEF AdBlue quality faults failures and engine power loss levels LEIL15WHL0609HA 3 7 20 ...
Страница 229: ...7 MAINTENANCE DEF AdBlue technical faults LEIL14WHL0392HA 4 7 21 ...