7 - MAINTENANCE
Every 10 hours
Engine oil level - Check
Check the engine oil level every 10 hours or each day, whichever occurs first.
Prior operation:
Keep all non-authorized personnel clear of the area. Park the machine on a firm, level surface and turn off the engine.
Service specifications
Type of oil
CASE AKCELA UNITEK NO. 1™ SBL CJ-4
621G Capacity (with filter change)
13.25 L
(
14 US qt
)
721G Capacity (with filter change)
13.25 L
(
14 US qt
)
1. The engine oil dipstick
(1)
is located on the right-hand
side of the engine, above the fuel fill location. Remove
the dipstick to check the engine oil level. Wipe the
dipstick clean and reinsert. The oil level should register
at the full mark.
NOTE:
this procedure is best performed at the beginning
of the work day with the engine cool and all oil drained to
the pan
RCPH10WHL899AAH
1
2. Locate the fill location
(2)
in the main engine compart-
ment. Add
CASE AKCELA UNITEK NO. 1™ SBL
CJ-4
, if necessary. Do not overfill engine oil.
7-43
Содержание 621G Stage IV
Страница 42: ...2 SAFETY INFORMATION Empty tool LEEN11T0024AA 20 2 22 ...
Страница 60: ...2 SAFETY INFORMATION 2 40 ...
Страница 137: ...3 CONTROLS AND INSTRUMENTS Inducement and validation re starts LEIL14WHL0394HA 2 3 77 ...
Страница 138: ...3 CONTROLS AND INSTRUMENTS Validation re start procedure LEIL15WHL0608HA 3 3 78 ...
Страница 150: ...3 CONTROLS AND INSTRUMENTS 3 90 ...
Страница 166: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 7 4 16 ...
Страница 168: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 9 4 18 ...
Страница 170: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 12 4 20 ...
Страница 208: ...6 WORKING OPERATIONS 6 18 ...
Страница 227: ...7 MAINTENANCE DEF AdBlue level faults failures and engine power loss levels LEIL15WHL0607HA 2 7 19 ...
Страница 228: ...7 MAINTENANCE DEF AdBlue quality faults failures and engine power loss levels LEIL15WHL0609HA 3 7 20 ...
Страница 229: ...7 MAINTENANCE DEF AdBlue technical faults LEIL14WHL0392HA 4 7 21 ...
Страница 370: ...7 MAINTENANCE 7 162 ...