7 - MAINTENANCE
Service
After a proper shutdown of the TIER 4B vehicle, the Supply Module can remain in a deactivated status for up to four
months under the following conditions:
• Store the vehicle in a dry environment, non-salty environment, and clean environment.
• Store the vehicle between
-40 °C
(
-40 °F
) and
25 °C
(
77 °F
).
• The relative humidity should be between
0 – 60%
.
• Protect the catalyst (muffler outlet) against direct rain and snow.
• Drain the
DEF/A
D
B
LUE
®
tank.
NOTE:
see “
DEF/A
D
B
LUE
®
tank refilling” section for important tank draining information.
• Flush the
DEF/A
D
B
LUE
®
tank with deionized water.
• Drain the deionized water.
• Do not disconnect any electrical connectors or
DEF/A
D
B
LUE
®
coolant connectors for the SCR system.
• If the vehicle will be in storage for more than 30 days, remove the ground cable(s) from the battery(s).
Storage, handling, and transport
NOTICE:
storage temperatures above
30 °C
(
86 °F
) greatly reduce the shelf life of DEF.
DEF/A
D
B
LUE
®
has a typical shelf life of 6-12 months. Refer to the S
HELF LIFE
table below.
In order for
DEF/A
D
B
LUE
®
to remain in a usable condition, storage requirements need to be met.
• Store between
-11 °C
(
12 °F
) and
30 °C
(
86 °F
).
• Use only an approved
DEF/A
D
B
LUE
®
container. Contact your dealer to obtain proper storage container(s).
• Keep container tightly closed.
• Keep container in a cool, well-ventilated area.
• Keep away from heat and direct sunlight.
To prevent decomposition of the
DEF/A
D
B
LUE
®
and the evaporation of water:
• Do not store
DEF/A
D
B
LUE
®
in vented containers.
• Protect
DEF/A
D
B
LUE
®
from sunlight in order to avoid any excessive temperature rise.
NOTICE:
frozen
DEF/A
D
B
LUE
®
has approximately a
7%
larger volume than the liquid.
At the first vehicle reactivation:
• Fill the
DEF/A
D
B
LUE
®
tank.
NOTE:
it is very important to fill the
DEF/A
D
B
LUE
®
tank before anyone starts or moves the vehicle. Otherwise SCR
fault codes will appear.
• Change the main filter on the Supply Module.
• Connect the ground cable(s) for the battery(s).
• Start the vehicle. Place the vehicle between
40 – 50%
load to start the
DEF/A
D
B
LUE
®
injection into the exhaust.
If a failure occurs:
• Perform a Urea Dosing System Test (UDST).
NOTE:
contact your local dealer to perform this procedure.
• Restart the vehicle.
• Place the vehicle between
40 – 50%
load to start the
DEF/A
D
B
LUE
®
injection into the exhaust.
7-29
Содержание 621G Stage IV
Страница 42: ...2 SAFETY INFORMATION Empty tool LEEN11T0024AA 20 2 22 ...
Страница 60: ...2 SAFETY INFORMATION 2 40 ...
Страница 137: ...3 CONTROLS AND INSTRUMENTS Inducement and validation re starts LEIL14WHL0394HA 2 3 77 ...
Страница 138: ...3 CONTROLS AND INSTRUMENTS Validation re start procedure LEIL15WHL0608HA 3 3 78 ...
Страница 150: ...3 CONTROLS AND INSTRUMENTS 3 90 ...
Страница 166: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 7 4 16 ...
Страница 168: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 9 4 18 ...
Страница 170: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 12 4 20 ...
Страница 208: ...6 WORKING OPERATIONS 6 18 ...
Страница 227: ...7 MAINTENANCE DEF AdBlue level faults failures and engine power loss levels LEIL15WHL0607HA 2 7 19 ...
Страница 228: ...7 MAINTENANCE DEF AdBlue quality faults failures and engine power loss levels LEIL15WHL0609HA 3 7 20 ...
Страница 229: ...7 MAINTENANCE DEF AdBlue technical faults LEIL14WHL0392HA 4 7 21 ...
Страница 370: ...7 MAINTENANCE 7 162 ...