Страница 1: ...2 ...

Страница 2: ...NSTRUCTION 6 FEATURES MAIN FUNCTIONS 6 TECHNICALSPECIFICATION 7 DESCRITION OFOVERALL 8 THE OPERATIONS 10 TEST MODE 12 SET MODE 15 BATTERYOPERATION 19 REMOTE CONTROL 20 ASSEMBLEAND DISASSEMBLY 21 ERROR MESSAGE TROUBLE SHOOTING 22 ...

Страница 3: ...4 PRECAUTIONS ...

Страница 4: ...5 ...

Страница 5: ...commended that you read this manual carefully so you may use this device to its full potential FEATURES Appropriatehoistscaleforindustrialfield UsefulZero TareandHoldfunction WeightBack Up Easytomove Beabletocontrolwithremotecontroller MAIN FUNCTIONS Usercanchangethestableconditionandrangeofdigital filteratuser soption SelfHardwaretest internalA Dvalue Batterypower keyandetc ...

Страница 6: ...b 0 5lb A D Speed 20 times second Tare Subtraction Full Capacity Display below zero ᅳ minus sign Excessive Weight Maximum 9d display OUEr Weight Display Type LCD 5 digit Sign 1 Inch Height Character Display ZERO TARE BAT POWER CHARGE Keys ON OFF ZERO TARE kg lb ᅳ HOLD Battery 7 2V 2A Li ion Use the Backlight Not use the Backlight 0 45 W 0 17 W Power and Battery consumption Approximate 22 Hours App...

Страница 7: ...8 DESCRIPTION OF OVERALL 1 OVERALL VIEW 2 DISPLAY ...

Страница 8: ...or a long time It makes the current weight within the zero range to zero 2 of maximum capacity Pressing ZERO key for 2 second can enter the TEST Mode It is used to weigh with a container If press the tare key at unload state Tare state is released Pressing the ON OFF key while tare key is pressed can enter the SET Mode It is used to weigh the moving things If you press this key once more in the ho...

Страница 9: ...0 THE OPERATION 1 POWER ON Press ON OFF key 2 ZERO OPERATION Press ZERO key when the zero point is drifted 3 TARE OPERATION Load tare on the hook Press TARE key 0 is displayed and the tare is subtracted ...

Страница 10: ...11 Remove tare on the hook Press TARE key The tare weight is cleared appers in the display window ...

Страница 11: ...the hook TEST MODE How to enter TEST Mode Pressing the key for 2 seconds in the normal mode enter the test mode with display the message Press the key or key to execute the test mode test2 5 is same sequence I f press the key in the test mode test mode is ended and then enter the normal mode Ref You can t enter the test mode while in the state of Hold orTare ...

Страница 12: ...hen enter the Normal mode Use the backlight only TEST 1 Move the next menu and then execute TEST Mode TEST 1 FUNCTION LCD TEST KEYS LCD SCREEN DESCRIPTION Display TEST 1 state Display all digits on the screen TEST 2 FUNCTION Load Cell and A D Conversion TEST KEYS LCD SCREEN DESCRIPTION Display TEST 2 state Display the digital value Corresponding to current weight ...

Страница 13: ...EST 3 state Display the temperature of IC CPU TEST 4 FUNCTION Battery TEST KEYS LCD SCREEN DESCRIPTION Display TEST 4 state Display the current value of battery TEST 5 FUNCTION Key Test KEYS LCD SCREEN DESCRIPTION Display TEST 5 state Pressing the key to test shows Power Zero Tare HoLd ...

Страница 14: ...s F 0 Setting the value of Digital Filter F 4 Weight Backup F 1 Setting the stable time of weight F 5 Setting the hold type F 2 Setting the stable range of weight F 6 Setting the time ofAuto Display Off F 3 Setting the Back Light Available keys KEYS DESCRIPTION Menu Cycle F0 F6F0 Increase the setting value Decrease the setting value Store the current setting value Not exit After storing all settin...

Страница 15: ...N 00 0 9 000 Setting the time within 0 5 second 09 Setting the time within 1 4 second F 2 FUNCTION Setting the stable range of weight step 0 5 division KEYS LCD SCREEN Setting value DESCRIPTION 00 0 9 00 Setting the range within 0 5 division 09 Setting the range within 4 0 division F 3 FUNCTION Setting the stable range of weight step 0 5 division KEYS LCD SCREEN Setting value DESCRIPTION 00 01 02 ...

Страница 16: ...oaded state Auto Average Hold Function If you press the Hold key in unloaded state after displaying the and the Hold function Is started JustWhen the weight is changed above the 1divison being displayed and the changed weight is hold If you want to release the Hold function have to press Hold key in unloaded state certainly When the Hold function is released being displayed the message Case 2 When...

Страница 17: ...ld key is pressed once the peak Hold function is started If Hold function is released you can see the massage If the Hold key is pressed again the Hold function is released If Hold function is released you can see the massage Ref If the weight is 0 lb or 0 kg this function is not operated F 6 FUNCTION Setting the time of Display off automatically KEYS LCD SCREEN Setting value DESCRIPTION 00 01 02 ...

Страница 18: ...AR PANELand connect adaptor with an scale like the following figure E If adaptor is connected with the scale Red lamp is on Power and Charge lamp is on Red charge Green complete charge F Time of charge is approximate 4 5 hours G If main power switch is off charge is not operate Red lamp is blinking Do check main power switch Main power switch is located Rear panel 2 Discharge If you use the batter...

Страница 19: ...arged voltage C Ascale turns power off automatically below the fixed voltage 75 of full charged voltage You can show LobAt message before turn power off REMOTE CONTROL FUNCTION RED LED Blinking whenever key is pressed ON OFF KEY Display ON OFF Toggle ZERO KEY It makes the current weight within the zero range to zero 2 of maximum capacity TARE KEY It is used to weigh with a container HOLD KEY Kg lb...

Страница 20: ...21 POWER Voltage 1 5V Size AASize 14 5 X 50 5 m m Battery Place batteries in correct polarity direction Note on the replacing battery Do not use new batteries with the used ASSEMBLE AND DISASSEMBLY ...

Страница 21: ...nt Check that the load cell is well connected with main unit Or calibration is done wrongly Don t lie the NC 1 on the flat If you can see the same massage continuously call your CAS dealer please Err09 Zero Key Cause The current weight exceeds zero range 2 of Maximum Capacity Management Unload the scale If you can see the same massage continuously call your CAS dealer please Err13 Zero Range when ...

Страница 22: ...If you can see the same massage continuously call your CAS dealer please oUEr Cause Too heavy object is put on platform sothat it may exceed the maximum capacity Management Never put the weight exceeding the maximum capacity If you can see the same massage continuously call your CAS dealer please If the load cell is damaged replace the load cell Ref The function of this manual can be changed witho...