manualshive.com logo in svg
background image

Features

• NSF® Certified
• Tare function
• Data hold
• Field calibration
• Removable stainless steel platform
• Batteries/power adapter
• Selectable units
• Overload indication
• Battery status indication
• On/off button
• Auto-off after 2 minutes
• Platform Size: 11.40 W x 7.08 H (in)/ 

29.0 W x 18.0 H (cm), removable

• Resolution: 0 lb:0.2 oz, 5 g 
• Power Adapter: 100-240VAC 50/60Hz input,  

9V DC (500mA) output (included)

• Two AAA 1.5V IEC LR03 alkaline batteries (included)

Note:

 Clean the scale before each use.

Important: DO NOT IMMERSE IN LIQUID.

Note:

 In the following instructions, names of the 

control buttons are shown in CAPS. Function 
information that appears on the display is shown in 

BOLD CAPS

.

Battery Installation

Replace battery when LCD becomes dim. 

bAtt

 appears 

on the display for 2 seconds before turning off when 
the batteries need to be replaced.
1. Power off the unit before installing the batteries.
2. Remove battery cover on the bottom by pressing the 

latch toward the battery cover and lifting up.

3. Install two AAA 1.5V IEC LR03 alkaline batteries 

observing polarity shown in compartment. 

4. Replace the battery cover until it clicks shut.

Power Adapter

Before using the external power adapter, make sure 
that the printed voltage complies with the local 
voltage.  

Note:

 Use only an original CDN power adapter (AD-AC3302). 

The use of another adapter is subject to approval by CDN.

1. Insert the adapter plug into the jack in the rear of 

the scale. 

2. To turn the scale on, press the ON/OFF button as 

described in 

Section A: On/Off

. The scale will remain 

on until turned off.  

Note:

 When the power adapter is plugged in, the auto-off 

feature is disabled.

Model: SD5502

ProAccurate

®

 Digital  

Portion Control Scale

55 pounds/25 kilograms 

by pounds:ounces and kilograms.grams

Содержание ProAccurate SD5502

Страница 1: ... before turning off when the batteries need to be replaced 1 Power off the unit before installing the batteries 2 Remove battery cover on the bottom by pressing the latch toward the battery cover and lifting up 3 Install two AAA 1 5V IEC LR03 alkaline batteries observing polarity shown in compartment 4 Replace the battery cover until it clicks shut Power Adapter Before using the external power ada...

Страница 2: ...of additional items 5 To clear the tare remove all items from the platform and press the TARE button The display is reset to zero G Field Calibration 1 When scale is off press and hold the ON OFF button until all segments are displayed is displayed first and then all segments When all segments are displayed press the ON OFF button 3 times within two seconds The display shows 11111 then 55555 and t...

Страница 3: ...aged battery and or distorted parts Do not tamper with the scale s internal components Doing so will invalidate the warranty and may cause unnecessary battery damage and or distorted parts Do not subject the scale to excessive exposure to direct sunlight The unit is not waterproof do not immerse it in any liquid which will result in faulty measurements To avoid deformation do not place the unit in...

Страница 4: ...the right to make improvements or changes to this document and the products and services described at any time without notice or obligation 1 Year Limited Warranty Any instrument that proves to be defective in material or workmanship excluding batteries within one year of original purchase will be repaired or replaced without charge upon receipt of the unit prepaid at CDN PO Box 10947 Portland OR ...

Отзывы: