63
7-3-2. Percent Mode Direct Input Method
Step
Display Screen and Key Input
Load
Tray
Descriptions
1
Press
key for about 3 seconds in the PCS Mode.
Empty
2
Screen display: “1.SAMPL” characters are blinking.
3
If
key is pressed
, “1. SAMPL” characters are blinking.
If
key is pressed
, “2. WEIGH” characters are blinking.
Select the
input method
as desired.
4
Press
+
keys.
5
Screen display: After “WEIGHT” is displayed, “0.000 KG” is
displayed.
Weight input
mode
6
Enter the weight of 100% using
~
keys, and
then press
key.
Save sample
weight
7
Screen display: It moves to Percent Mode after displaying
“End”.
Note 1. If
key is pressed during operations in the Percent MODE, it shows the current
weight for 3 seconds and then returns to the PCS Mode.
Note 2. If the value of Piece Weight to a function key (F17 or F18), you may confirm the unit
weight of 1 PCS.