41
5-3-2. RS-232 (Serial Communication) Function
F26
Function
Set Device ID
Display Meaning
F26. 00
Device ID 00
Setting range
(00 ~ 99)
F26. 99
Device ID 99
Note 1. This function enables to use the unique indicator ID in the command mode.
F27
Function
Set Parity Bit – RS232C & PRT
Display Meaning
F27. 0
Data bit 8, stop bit 1, parity bit: none
F27. 1
Data bit 7, stop bit 1, parity bit: even number
Setting range
(0 ~ 2)
F27. 2
Data bit 7, stop bit 1, parity bit: odd number
Note 1. F26 and F27 apply commonly to 2 serial communications (RS23C and PRT).
Содержание CI-200 Series
Страница 1: ...2 ...
Страница 11: ...12 2 Specifications in Appearance 2 1 External Dimension CI 200A CI 201A ...
Страница 12: ...13 CI 200S CI 200SC ...
Страница 13: ...14 2 2 Front Panel Descriptions CI 200A CI 201A ...
Страница 15: ...16 CI 200S CI 200SC ...
Страница 78: ...79 MEMO ...
Страница 79: ...80 MEMO ...
Страница 80: ...81 MEMO ...
Страница 81: ...82 ...
Страница 82: ...83 ...