4537 • C3 7/06
43
AC ELECTRICAL SYSTEM
SECTION 3
Generator Running Indicator
This indicator illuminates when the optional generator is operating. To provide
the generator’s power to your boat’s AC electrical system, switch the appropriate
Generator circuit breaker group “ON.”
Microwave
This breaker controls the flow of electricity to the galley’s microwave. Switch
this breaker “ON” to supply power to the microwave. Refer to the OEM
information for details on operating the microwave.
Power Available Indicator
This indicator illuminates when your boat is connected to a working shore
power source. To provide that power to your boat’s AC electrical system, switch
the appropriate Shore circuit breaker group “ON.”
Range
This breaker controls the flow of electricity to the galley’s stove. Switch this
breaker “ON” to supply power to the stove. Refer to the OEM information for
details on operating the stove.
NOTE:
If your boat contains the optional propane stove, an additional circuit
breaker labeled Propane on the DC Control Center must be switched “ON” to
operate the stove. Refer to the OEM information for details on operating the propane
stove.
Receptacles - Aft
This breaker controls the flow of electricity to the receptacles in the aft (master)
stateroom and aft head. Switch this breaker “ON” to supply power to these
receptacles. Use the receptacles as you would the outlets in your home.
NOTE:
If this circuit breaker is “ON” but power is not available at any of the
receptacles in this circuit, the circuit’s GFCI breaker may have tripped. Refer to
Ground Fault Circuit Interrupters later in this section for more information.
Receptacles - Exterior
This breaker controls the flow of electricity to the receptacles on the bridge.
Switch this breaker “ON” to supply power to these receptacles. Use the
receptacles as you would the outlets in your home.
NOTE:
If this circuit breaker is “ON” but power is not available at any of the
receptacles in this group, the circuit’s GFCI breaker may have tripped. Refer to
Ground Fault Circuit Interrupters later in this section for more information.
Receptacles - Forward
This breaker controls the flow of electricity to the receptacles in the forward
(guest) stateroom and forward head. Switch this breaker “ON” to supply power
to these receptacles. Use the receptacles as you would the outlets in your home.
NOTE:
If this circuit breaker is “ON” but power is not available at any of the
receptacles in this group, the circuit’s GFCI breaker may have tripped. Refer to
Ground Fault Circuit Interrupters later in this section for more information.
Содержание 45 COCKPIT MOTOR
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 28: ......
Страница 43: ...4537 C3 7 06 31 DC ELECTRICAL SYSTEM SECTION 2 DC Wiring Schematic V8083D 11 7 8 05 ...
Страница 44: ......
Страница 63: ...4537 C3 7 06 51 AC ELECTRICAL SYSTEM SECTION 3 AC Wiring Schematic 125V 60Hz V8084C 4 9 19 02 ...
Страница 64: ...52 4537 C3 7 06 AC ELECTRICAL SYSTEM SECTION 3 230V 50Hz V8089C 4 9 19 02 ...
Страница 118: ......
Страница 132: ......
Страница 139: ...4537 C3 7 06 127 WARRANTY AND PARTS SECTION 9 Bill of Material ...
Страница 140: ......
Страница 141: ...4537 C3 7 06 129 WARRANTY AND PARTS SECTION 9 Carver Limited Warranty ...