AC E
LECTRICAL
S
YSTEM
3327 12/04
S
ECTION
3
Problem
Possible Cause
Possible Solution
Voltmeter on the AC
Control Center reads
zero volts.
No power at the recep-
tacles, but the voltmeter
on the AC Control
Center indicates an
adequate voltage level.
The Shore #1 or Shore
#2 Main circuit breaker
on the AC Control
Center trips immedi-
ately after being reset.
Shore power cord is not con-
nected.
There is no power at the shore
power source box.
The circuit breaker installed in
the shore power source box is
“OFF.”
The AC Main circuit breaker
group is “OFF.”
The shore power cord failed.
The generator ran out of fuel.
The safety circuit breaker on the
generator control panel is “OFF.”
The generator failed.
The voltmeter failed.
A wire within the AC electrical
system is loose or disconnected.
The Shore #1 or Shore #2 Main
circuit breaker on the AC Control
Center is “OFF.”
The Receptacles breakers on the
AC Control Center are “OFF.”
A GFCI tripped.
The circuit breaker failed.
Connect the shore power cord.
Contact marina management.
Switch the circuit breaker “ON.”
Switch the AC Main “ON.”
Replace the cord.
Check the fuel level in the port fuel
tank; refuel if necessary.
Switch the circuit breaker “ON.”
Refer to the OEM information.
Contact a qualified electrician to
make the appropriate repairs.
Contact a qualified electrician to
make the appropriate repairs.
Contact a qualified electrician to
make the appropriate repairs.
Switch the circuit breaker “ON.”
Switch the circuit breakers “ON.”
Locate the tripped GFCI and press
the Reset button.
Contact your Carver Dealer to
have the circuit breaker replaced.
3.7 Troubleshooting the AC Electrical System
Содержание 33 SUPER SPORT
Страница 1: ...33 Super Sport Owner s Guide HIN CDR 2005 Version 1...
Страница 2: ......
Страница 4: ......
Страница 13: ...Engine Room 9 7 4 Bill of Material 9 8 Carver Limited Warranty 9 9 TABLE OF CONTENTS...
Страница 14: ......
Страница 18: ......
Страница 38: ...BOATING SAFETY 3327 11 04 SECTION 1...
Страница 53: ...3327 12 04 DC ELECTRICAL SYSTEM SECTION 2 2 5 DC Schematic 3327 300 016a...
Страница 54: ...DC ELECTRICAL SYSTEM 3327 12 04 SECTION 2 3327 300 016b...
Страница 71: ...3327 12 04 AC ELECTRICAL SYSTEM SECTION 3 3 8 AC Schematic 3327 300 015a...
Страница 72: ...AC ELECTRICAL SYSTEM 3327 12 04 SECTION 3 3327 300 015b...
Страница 111: ...3327 12 04 OPERATING AND MANEUVERING SECTION 6 TRACKING FORWARD PROPS ONLY TRACKING ASTERN PROPS ONLY...
Страница 148: ...WINTERIZATION AND STORAGE 3327 12 04 SECTION 8...
Страница 151: ......
Страница 163: ...3227 12 04 WARRANTY AND PARTS SECTION 9 9 9 Carver Limited Warranty...
Страница 164: ...WARRANTY AND PARTS 3327 12 04 SECTION 9...