2–13
62-11637
k. Display Module Keys
ALARM Key
The ALARM key allows viewing of the
alarms stored in the system.
UP ARROW and DOWN ARROW
Keys
These keys allow scrolling through the
selections presented.
EQUAL Key (ENTER)
The EQUAL key is used to confirm a
selection and lock it into the memory.
START-STOP/CONTINUOUS Key
Pressing this key toggles between
Start-Stop and Continuous Operation.
DEFROST Key
The MANUAL DEFROST key may be
used to initiate a defrost cycle when
the required conditions are met.
MENU Key
Pressing the MENU key displays the
various soft keys in the MessageCen-
ter. The selections offered are depen-
dent on the operator’s status: Driver,
Advanced User or Technician. Refer to
for Driver & Advance User
mode and
for Technician
mode menu selection descriptions.
USB Interface Port
The USB Interface Port is used for
installing software updates, options,
configurations, functional parameters
and downloading of data from the Data
Link data recorder.
2.6
OPTIONS
2.6.1
Light Bar
The Light Bar is an external indicator light which can be
seen in the driver’s rear view mirror from the cab of the
tractor. The green LED indicates “STATUS OK”. The
amber LED indicates “CHECK UNIT”. The amber light
is illuminated when the control system illuminates the
alarm light. Alarms can be read on the display.
Figure 2.9 Light Bar
2.6.2
Remote Switch(es)
The unit is provisioned to connect a door switch (DS)
and/or a remote switch (REMS1) directly to the control
system at the SVM.
• Two types of switches may be used:
1. A switch with contacts that are open when the
door is open or the remote switch is activated.
2. A switch with contacts that are closed when the
when the door is open or the remote switch is
activated.
• Four Configurations are available:
1. Activate an alarm only while the switch is acti-
vated.
2. Activate an alarm and shut the unit down while the
switch is activated. The unit will remain shut down
for a minimum of 3 minutes under this setting.
3. Activate the alarm and bring the engine into low
speed while the switch is activated.
4. Record the switch activation in the DataLink
data recorder.
• If configured to shut the unit down or bring the
engine to low speed an additional choice will be
available. The additional choice allows the unit to
be set so that the configured action will always
take place OR the configured action will only take
place when the ambient temperature is below a
certain temperature. For example, if the shut-
down/low speed temperature choice is set to 77°F
(25°C) the unit will only shutdown/ go to low speed
if the ambient temperature is below 77°F (25°C).
• Additionally a Functional Parameter “override”
setting will be available when the switch is con-
figured to shut the unit down. The Functional
Parameter may be set to “YES” or “NO”. If the
Parameter is set to “NO” the configured action
will not be overridden. If the Parameter is set to
“YES”, the alarm will be activated but the unit will
not shutdown.
DEFROST
DEFROST
START
‐
STOP
CONTINUOUS
START/STOP
START
‐
STOP
DEFROST
START
‐
STOP
MENU
ALARM
GREEN
AMBER