62-11637
5–18
SETPOINT(S) & RANGE LOCK
DECIMAL
DISPLAYED
DISPLAYED = setpoint will be shown with a decimal
and temperatures may be selected to a tenth of a de-
gree.
NOT DISPLAYED
NOT DISPLAYED = setpoint will not be shown with
a decimal. All other temperatures will still be dis-
played with a decimal.
MIN SETPOINT
-
22°F
TO 90°F
(
-30C
to 32°C)
in 0.1°F or °C increments
Indicates to the main microprocessor the desired
minimum allowable set point.
MAX SETPOINT
-22°F TO
90°F
(-30C to
32°C
)
in 0.1°F or °C increments
Indicates to the main microprocessor the desired
maximum allowable setpoint.
RANGE 1 LOCK
OR
RANGE 2 LOCK
OFF
START-STOP
CONTINUOUS
OFF = If both Range Locks are OFF, the unit will op-
erate normally.
If either Range 1 or Range 2 is not OFF, the unit will
operate as selected whenever the setpoint is within
that range
START-STOP = The unit will always operate in
Start-Stop whenever the setpoint is between the
minimum & maximum temperatures for that range
(refer to the following sub-configurations).
CONTINUOUS = The unit will always operate in
Continuous Run whenever the setpoint is between
the minimum & maximum temperatures for that
range (refer to the following sub-configurations).
• RANGE 1 (or 2) MINIMUM
TEMPERATURE
-22°F TO
90°F
(-30C to
32°C
)
in 0.1°F or °C increments
Select the lowest temperature desired for this range.
• RANGE 1 (or 2) MAXI-
MUM TEMPERATURE
-22°F TO
90°F
(-30C to
32°C
)
in 0.1°F or °C increments
Select the highest temperature desired for this range
START-STOP SETTINGS
CURRENT FOR S/S SHUT-
OFF
7.0A
1A TO 10A (in 0.5A incre-
ments)
In Start-Stop Operation the charging current must
drop below this value before the unit is allowed to
shut down.
VOLTAGE FOR S/S RE-
START
12.2V
12.0 TO 12.8V
The engine will restart from a Start-Stop Off cycle or
a Sleep Mode Off cycle when the battery drops to
this value.
A lower selection may result in a longer off cycle
(based on battery voltage) and possibly overall
shorter battery life. A higher selection may result in a
shorter off cycle (based on battery voltage) and pos-
sibly overall longer battery life.
ENGINE TEMP FOR S/S
RESTART
32°F (0°C)
10°F to 32°F (-12.2°C to 0°C)
The engine will restart from a Start-Stop Off cycle or
a Sleep Mode Off cycle when the engine coolant
temperature drops to this value.
Table 5–1 Configuration Settings
Configuration
Selections
Description
Содержание Transicold X4 7300
Страница 21: ...62 11637 1 6 1 3 SAFETY DECALS ...
Страница 22: ...1 7 62 11637 62 03958 ...
Страница 23: ...62 11637 1 8 ...
Страница 24: ...1 9 62 11637 ...
Страница 119: ...62 11637 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Страница 278: ......