5–1
62-11637
SECTION 5
CONTROL SYSTEM INTERFACE
5.1
INTERFACE METHODS
There are four methods for interfacing with the APX control system:
1. Driver/Advanced User Interface - Driver & Advanced User Interface activities such as start, stop, Pretrip,
reading alarms, reading data and changing Functional Parameters may all be performed using the display
mounted keys (refer to
2. Technician Mode - code based access. Technician Mode includes: technician hour meters, inactive alarms,
configuration settings, Component Test Mode and Service Mode.
3. USB memory device - Activities using the USB memory device include, creation of the device, PC Mode,
downloading data files, installing software, and transferring configuration files.
4. TRU-Tech/TRU-View - Access using a computer and service cable.
5.2
TECHNICIAN MODE
The Technician Mode allows the technician to view inactive alarms, view additional hour meters, work with Config-
urations, test the unit components and/or service the refrigeration system. Instructions for entering the Technician
Mode are provided in
while information on these operations is provided in the following sub-paragraphs.
Figure 5.1 Technician Mode
1. With the system powered up (START/RUN-OFF switch in the START/RUN position) or in PC Mode press
the MENU key until TECH MODE is displayed. If TECH MODE does not display, place the system in
2. Press the TECH MODE key. Enter the master technician PIN code. The factory installed master technician
PIN code is 7435. Enter this code by pressing the 3&4 keys simultaneously, then pressing the 4 key, then
the 3 key, then the 1&4 keys simultaneously. Once the code is entered, press the “=” key to enter the Tech-
nicians Menu.
CONTINUOUS
START/STOP
MENU
ALARM
COOL
DIESEL
START/STOP
INTELLISET
Viewing Menu Soft Key
Selections
Press Menu Key to Scroll
PRETRIP HOUR
METERS
UNIT
DATA
DEFROST
COOL
DIESEL
START/STOP
TECH
MODE
Viewing Menu Soft Key
Selections
Press Menu Key to Scroll
1
3
TECHNICIANS MENU (1 OF 4)
BACK
EXIT
CONFIGURATION SETTINGS
COMPONENT TEST MODE
SERVICE MODE
CANCEL TECHNICIAN MODE/PIN ACCESS
END OF LIST
COOL
DIESEL
START/STOP
STATUS OK
36
36
.2
BOX TEMPERATURE F
SETPOINT F
ENTER CODE