4–31
T-340
Cd48
Dehumidification /
Bulb Cargo Mode
Parameter Selection
Initially Cd48 will display current dehumidification-mode; bUlb - bulb cargo
mode, dEhUM - normal dehumidification, or OFF - off. This display is steady.
Pressing the ENTER key will take the interface down into a hierarchy of param
-
eter selection menus (mode, setpoint, evaporator speed, DTT setting). Pressing
the ENTER key in any parameter selection menu commits to selection of the cur
-
rently displayed parameter and causes the interface to descend into the next pa
-
rameter selection menu. All parameter selection menus alternate between a
blank display and the current selection in the right hand display.
Pressing the CODE SELECT key in a selection menu cancels the current selec
-
tion activity and ascends back up to the next higher selection menu (or to Cd48
display mode if that is the next higher).
If the operator does not press any key for five seconds the interface reverts to
normal system display and the current selection menu is cancelled, but any pre
-
viously committed changes are retained.
Available parameters and parameter ranges are a function of configuration op
-
tions and previously selected parameters as indicated above.
Whenever any pretrip test is initiated, dehumidification-mode goes to OFF.
Whenever dehumidification-mode goes to OFF:
• Dehumidification control setpoint goes to 0% RH internally but will then
initialize to 95% RH when dehumidification-mode leaves OFF.
• Evaporator speed select goes to Alt for units without PWM Compressor
Control (Cnf57 = Out), Evaporator speed select goes to Hi for units with
PWM Compressor Control (Cnf57 = In).
• DTT setting goes to 25.6°C or 18.0°C, depending on Cnf41.
Whenever dehumidification-mode is set to bUlb, DTT setting goes to 18.0°C if it
had been set higher.
Whenever dehumidification-mode is set to dEhUM, DTT setting goes to 25.6°C
or 18.0°C, depending on Cnf41.
For units without PWM Compressor Control (Cnf57 = Out):
• Whenever dehumidification control setpoint is set below 65% RH evapo
-
rator speed select goes to LO if it had been set to Hi.
• Whenever dehumidification control setpoint is set above 64% RH evapo
-
rator speed select goes to Alt if it had been set to LO.
For units with PWM Compressor Control (Cnf57 = In):
• Whenever dehumidification control set point is set below 60% RH, the
evaporator fan speed is set to LO, the user has the ability to set the evap
-
orator fan speed to Hi via the keypad.
• Whenever dehumidification control set point is set equal to or above 60%
RH, the evaporator fan speed is set to Hi, the user has the ability to set
the evaporator fan speed to LO via the keypad.
Display Only Function
- Cd49 is a display only function.
Cd49
Days Since Last
Successful Pre-trip
Displays the number of days since last successful pretrip sequence.
Press the ENTER key to view the number of days since the last successful pre
-
trip for Auto1, Auto2, and Auto2 in sequence.
Press the CODE SELECT key to step back through the list and ultimately to exit
the Cd49 display.
Table 4–5 Controller Function Codes
Code
Title
Description
Содержание Transicold 69NT40-561-001
Страница 2: ......
Страница 4: ......
Страница 14: ......
Страница 22: ......
Страница 36: ......
Страница 92: ......
Страница 159: ...7 47 T 340...
Страница 163: ...8 3 T 340 Figure 8 2 Schematic Diagram for Standard Unit Configuration Based on Drawing 62 11271 Rev A...
Страница 169: ...8 9 T 340 Figure 8 8 Schematic and Diagram for Lower Vent Position Sensor VPS Option...
Страница 170: ...T 340 8 10 Figure 8 9 Unit Wiring Diagram for Standard Unit Configuration With 3 Phase Condenser Fan Motors...
Страница 172: ...T 340 8 12 Figure 8 10 Unit Wiring Diagram for Single Phase Condenser Fan Motor and Optional Heater...
Страница 173: ...8 13 T 340 Unit Wiring Diagram for Single Phase Condenser Fan Motor and Optional Heater Based on Drawing 62 66721...
Страница 174: ...T 340 8 14 Figure 8 11 Unit Wiring Diagram for Configuration With eAutoFresh and Emergency Bypass Options...
Страница 176: ......
Страница 180: ......
Страница 181: ......