Display Only Function
- Cd44 is a display only function.
Cd44
eAutoFresh Values /
CO
2
Sensor Status
Code Cd44 displays the eAutoFresh CO
2
and O
2
values (CO
2
and O
2
) and CO
2
and O
2
limits (CO
2
LIM and O
2
LIM), respectively.
This function code will be dashed out if not configured for eAutofresh.
This function code will be dashed if CO
2
sensor is not detected, and a sensor is
not expected (didn’t have one previously).
This function code will display “ChECK” if a CO
2
sensor has not been auto-de
-
tected at the most recent power-up and was detected at a previous power-up. If
“ChECK” is displayed and the ENTER key is pressed, “SEnSr” is displayed with
the choices of “YES” and “no”:
“YES” - sensor should be remembered as detected (present)
“no” - sensor should not be remembered as being detected (not present)
Configurable Functions
- Cd45 through Cd48 are user-selectable functions. The operator can change the value
of these functions to meet the operational needs of the container.
Cd45
Vent Position Sensor
(VPS) Position
Values: 0 to 240 for UPPER / 0 to 225 for LOWER
This function code will be dashed out if not configured for VPS.
When configured for VPS, Cd45 displays the current vent position in units of 5
CMH (units displayed as “CM”) or CFM (units displayed as “CF”) depending on
the selection of Cd46 (Airflow display units), Cd28 (Metric/Imperial) or the press
-
ing of the deg C/F key.
Cd45 will display whenever the control detects movement via the sensor unless
AL50 is active. Cd45 will display for 30 seconds, then time out and return to the
normal display mode.
Cd46
Airflow Display Units
Selects the airflow units to be displayed by Cd45 if configured for Vent Position
Sensor or displayed by “USER/FLO” under Cd43 if configured for Autoslide.
CF = Cubic Feet per Minute
CM = Cubic Meters per Hour
bOth = Displays CF or CM depending on the setting of Cd28 (Metric/Imperial) or
the pressing of the degree C/F key.
Cd47
Variable Economy
Temperature Setting
The variable temperature “degrees C or degrees F” setting is used with economy
mode. Function code is “----” when unit is not configured for economy mode.
Table 4–5 Controller Function Codes
Code
Title
Description
Содержание Transicold 69NT40-561-001
Страница 2: ......
Страница 4: ......
Страница 14: ......
Страница 22: ......
Страница 36: ......
Страница 92: ......
Страница 159: ...7 47 T 340...
Страница 163: ...8 3 T 340 Figure 8 2 Schematic Diagram for Standard Unit Configuration Based on Drawing 62 11271 Rev A...
Страница 169: ...8 9 T 340 Figure 8 8 Schematic and Diagram for Lower Vent Position Sensor VPS Option...
Страница 170: ...T 340 8 10 Figure 8 9 Unit Wiring Diagram for Standard Unit Configuration With 3 Phase Condenser Fan Motors...
Страница 172: ...T 340 8 12 Figure 8 10 Unit Wiring Diagram for Single Phase Condenser Fan Motor and Optional Heater...
Страница 173: ...8 13 T 340 Unit Wiring Diagram for Single Phase Condenser Fan Motor and Optional Heater Based on Drawing 62 66721...
Страница 174: ...T 340 8 14 Figure 8 11 Unit Wiring Diagram for Configuration With eAutoFresh and Emergency Bypass Options...
Страница 176: ......
Страница 180: ......
Страница 181: ......