![Carrier 40UH050 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/carrier/40uh050/40uh050_installation-start-up-and-service-instructions-manual_2562604012.webp)
12
Table 2 — Electric Heater Data for Units with PSC Motor
LEGEND
*Cooling coil must be left-hand coil connections only.
NOTES:
1. LAT (leaving air temperature) is at maximum fan speed with
entering air temperature at 70°F.
2. Face and bypass units are available only with 3 elements.
3. Electric heat is available in the reheat only position.
4. The PSC motor is not available on unit size 200.
UNIT
HP
NOMINAL
V/Ph/Hz
NUMBER OF
ELEMENTS
FLA
LAT (F)
MCA
MOCP
TOTAL
CAPACITY (kW)
40UV050
(at 500 cfm)
1
/
5
208/1/60
3
17.2
90
21.5
25
3.2
4
22.2
97
27.8
30
4.2
5
27.3
104
34.1
35
5.3
6
32.3
110
40.4
45
6.3
240/1/60
3
19.5
97
24.4
25
4.2
4
25.3
106
31.7
35
5.6
5
31.2
115
39.0
40
7.0
6
37.0
124
46.3
50
8.4
277/1/60
3
16.8
97
21.0
25
4.2
4
21.8
106
27.3
30
5.6
5
26.9
115
33.6
35
7.0
6
31.9
124
39.9
40
8.4
208/3/60
3
10.8
90
13.5
15
3.2
4
15.8
97
19.8
20
4.2
5
19.5
104
24.4
25
5.3
6
19.5
110
24.4
25
6.3
240/3/60
3
12.1
97
15.1
20
4.2
4
17.9
106
22.4
25
5.6
5
22.2
115
27.8
30
7.0
6
22.2
124
27.8
30
8.4
460/3/60
3
6.0
97
7.5
15
4.2
4
8.9
106
11.1
15
5.6
5
11.0
115
13.8
15
7.0
6
11.0
124
13.8
15
8.4
40UV,UH075
(at 750 cfm)
1
/
5
208/1/60
3
23.7
89
29.6
30
4.5
4
30.9
96
38.6
40
6.0
5
38.1
102
47.6
50
7.5
6
45.3
108
56.7
60
9.0
240/1/60
3
27.0
96
33.8
35
6.0
4
35.3
104
44.2
45
8.0
5
43.7
113
54.6
60
10.0
6
52.0
121
65.0
70
12.0
277/1/60
3
23.3
96
29.1
30
6.0
4
30.5
104
38.1
40
8.0
5
37.7
113
47.1
50
10.0
6
44.9
121
56.2
60
12.0
208/3/60
3
14.5
89
18.2
20
4.5
4
21.7
96
27.2
30
6.0
5
27.0
102
33.8
35
7.5
6
27.0
108
33.8
35
9.0
240/3/60
3
16.5
96
20.6
25
6.0
4
24.8
104
31.0
35
8.0
5
30.9
113
38.6
40
10.0
6
30.9
121
38.6
40
12.0
460/3/60
3
8.2
96
10.2
15
6.0
4
12.3
104
15.4
20
8.0
5
15.4
113
19.2
20
10.0
6
15.4
121
19.2
20
12.0
FLA
—
Full Load Amps
LAT
—
Leaving-Air Temperature at 70°F Entering-Air
Temperature
MCA
—
Unit Minimum Circuit Ampacity
MOCP —
Maximum Overcurrent Protection (Maximum Fuse Size
or Circuit Breaker Amps)
PSC
—
Permanent Split Capacitor