36
Outdoor Fan Motor
(Model: YDK53-6N)
Measure the resistance value of each winding by using the multi-meter.
Outdoor Fan Motor
(Model: YDK100-6T)
Measure the resistance value of each winding by using the multi-meter.
Indoor Fan Motor
Model: YDK36-4C(A)
Measure the resistance value of each winding by using the multi-meter.
Position
Resistance Value
Black - Red
87
Ω (20
℃
)
Red -Yellow
162
Ω (20
℃
)
Position
Resistance Value
Black - Red
63
Ω (20
℃
)
Red -Yellow
57
Ω (20
℃
)
Position
Resistance Value
White - Red
272
Ω±8% (20
℃
)
Brown- Black
94
Ω±8% (20
℃
)
Содержание 38LUVH055N
Страница 9: ...6 4 Refrigerant cycle diagram...
Страница 10: ...7 5 Wiring diagram 5 1 Indoor Unit 42LUVH055N 42LUVH065N 42LUVH075N...
Страница 11: ...8 5 2 Outdoor Unit 38LUVH055N 38LUVH065N 38LUVH075N...
Страница 33: ...30...