In drying mode, if room temperature is lower than 10
℃
, compressor will stop and not resume until room temperature
climbs up to 12
℃
.
8.6.3 Evaporator anti-freezing protection, condenser high temperature protection and outdoor unit frequency limit are
valid, and they are the same as that in cooling mode.
8.6.4 Horizontal louver action is the same as that in cooling mode.
8.7 Heating mode
8.7.1 Indoor fan action:
Anti-cold-wind function.
If the compressor stops caused by room temperature rising, indoor fan will be forced to run 127 seconds with breeze.
During this period, anti-cold-wind is disabled. After this, anti-cold
–wind function is available.
If the machine runs in rating capacity test mode, indoor fan runs with rating speed, and anti-cold-wind is disabled.
8.7.2 Indoor fan speed can be set as high, medium, low or auto grade, but anti-cold-wind function is preferential.
Auto fan action in heating mode.
Δ
T=
(o
o
m
te
m
p
)
–
(s
e
tt
in
g
T
e
m
p
)
medium
2.5
2.0
1.5
1.0
℃
low
high