35
9.3 Key parts checking.
9.3.1. Compressor checking
(Model: DA150S1C-20FZ)
Measure the resistance value of each winding by using the multi-meter.
(Model: DA250S2C-30MT)
Measure the resistance value of each winding by using the multi-meter.
9.3.2 Outdoor Fan Motor
(Model: YDK55-6G)
Measure the resistance value of each winding by using the multi-meter.
Position
Resistance Value
Blue - Red
0.95
Ω
(20
℃
)
Blue - Black
Red - Blue
Position
Resistance Value
Blue - Red
0.55
Ω
(20
℃
)
Blue - Black
Red - Blue
Position
Resistance Value
Black - Red
191
Ω (20
℃
)
Red -Yellow
220
Ω (20
℃
)