T-375
5–14
5.6.2
Check and Replace Isolators / Shockmounts
CAUTION
!
Continued operation with failed shockmounts may result in engine or generator damage. When
a shockmount has been cut, split, abraded or has flared due to normal deterioration, it must be
replaced. Damage to the mounts may not be visible when installed and under load from the
component. To correctly inspect shockmounts, they must be removed.
Engine Isolator / Shockmount Replacement
1. Use the two lift eyes to lift and support the engine.
2. Remove truss, unidrive isolator and all hardware as shown in
3. Remove all hardware as shown in
4. Raise the engine just enough to remove the shockmounts as shown in
.
5. Install new shockmounts.
6. Lower the engine enough to assemble hardware as shown and torque per
7. Remove chains from the lift eyes.
Generator Shockmount Replacement
1. Use the two lift eyes to lift and support the engine.
2. Remove shockmount hardware.
3. Raise the generator just enough to remove the shockmounts as shown in
4. Install new shockmounts.
5. Lower the engine enough to assemble hardware as shown and torque. See
6. Remove chains from the lift eyes.