5–11
T-375
20. Apply Loctite 262 to the generator coupler bolt. Install with washer and torque to 38 N-m (28 ft-lbs). See
NOTE
In order to torque generator torsional dampener gear bolt, use a strap wrench or similar device to
secure the dampener while torquing the bolt.
Figure 5.7 Generator Coupler Bolt
21. Remove the generator support plate from the old generator and install it onto the new generator.
22. With the torsional dampener and support plate installed on the new generator, lift and position the generator
so that the generator mounting holes (12) are lined up with the engine mounting holes.
23. Insert two generator alignment bolts (2 1/2”) to temporarily align / secure the generator to the engine.
Tighten the bolts enough so that the torsional dampener on the generator is touching the aluminum housing
on the engine. Do not over tighten the alignment bolts, as they will bottom out on the engine bell housing.
.
NOTICE
Align the torsional dampener and aluminum housing by rotating either one to seat correctly.
Figure 5.8 Generator Alignment Bolt