Broadmore 1750 - Release 4.6
2-13
Planning
and
Ordering Guide
Installation Planning Factors
Installation Planning Factors
The Broadmore 1750 is designed and delivered ready for installation in a standard 19"
or 23" relay or EIA equipment rack. Several factors should be considered and some
decisions made to ensure a smooth installation that meets all requirements. Installation
factors and system specifications are shown in the following tables.
Factor
Consideration
Access
Clearance
Broadmore 1750 requires the following access clearances for
service and maintenance:
Front: 24
"
Rear: 4
"
Top: 1.75
"
(Broadmore 1750 units may be stacked without this
clearance.)
Power
Source
DC Power: –48 VDC at 5 amperes is connected to the rear of the
Broadmore chassis. A second –48 VDC source may be connected
for redundancy.
Optional AC Power Supply Tray: Converts 110/240 VAC (50-60
Hz) to –48 VDC. Rack mounted tray (3.5
"
high) installs
immediately below Broadmore chassis and can hold two power
supplies. Unit comes with one power supply and cables. A second
power supply with cables can be added to provide redundant DC
power to the Broadmore. AC and DC power connections are at the
rear of the unit. The DC cable is approximately 3.5 ft. long.
Содержание Broadmore 1750
Страница 1: ...Broadmore TM 1750 USER MANUAL Part Number 770 0020 DC Product Release 4 6 January 2008 ...
Страница 24: ...xii Broadmore 1750 Release 4 6 Table of Contents ...
Страница 50: ...1 26 Broadmore 1750 Release 4 6 Product Description Alarm Power Module IOM ...
Страница 69: ...CHAPTER 3 Receipt of Product In this Chapter Receipt 3 2 Unpacking 3 2 Inspection 3 3 ...
Страница 72: ...3 4 Broadmore 1750 Release 4 6 Receipt of Product Damage Reporting ...
Страница 82: ...4 10 Broadmore 1750 Release 4 6 Chassis Installation and Grounding AC Power Supply Tray ...
Страница 114: ...6 16 Broadmore 1750 Release 4 6 Electrical Installation Software ...
Страница 188: ...7 74 Broadmore 1750 Release 4 6 Configuration Help ...
Страница 199: ...Broadmore 1750 Release 4 6 8 11 Maintenance and Troubleshooting Slot Statistics for NIM SAM Cards ...
Страница 200: ...8 12 Broadmore 1750 Release 4 6 Maintenance and Troubleshooting Slot Statistics for NIM SAM Cards ...
Страница 234: ...8 46 Broadmore 1750 Release 4 6 Maintenance and Troubleshooting Summary of Front Panel LEDs ...
Страница 244: ...9 10 Broadmore 1750 Release 4 6 Command Line Interface About Command ...
Страница 266: ...10 22 Broadmore 1750 Release 4 6 Security Management FTP Login ...
Страница 302: ...11 36 Broadmore 1750 Release 4 6 Security Management FIPS Mode sshdShow ...
Страница 311: ...Broadmore 1750 Release 4 6 11 45 Security Management FIPS Mode Logging in with SecurID Disabled ...
Страница 314: ...11 48 Broadmore 1750 Release 4 6 Security Management FIPS Mode Logging in with SecurID Enabled ...
Страница 318: ...11 52 Broadmore 1750 Release 4 6 Security Management FIPS Mode Sanitation Procedures ...
Страница 362: ...12 44 Broadmore 1750 Release 4 6 SNMP Configuration Notify Profiles ...
Страница 363: ...APPENDIX A Technical Specifications In this Appendix Broadmore 1750 Platform A 2 Broadmore Modules A 6 ...
Страница 370: ...A 8 Broadmore 1750 Release 4 6 Technical Specifications E3 Unstructured Circuit Emulation SAM ...
Страница 373: ...APPENDIX C Software Error Messages In this Appendix Overview System Errors Setup Errors ...
Страница 383: ...APPENDIX E Chassis Differences ...
Страница 386: ...E 4 Broadmore 1750 Release 4 6 Chassis Differences Software Differences ...
Страница 394: ...F 8 Broadmore 1750 Release 4 6 IPv6 Support Deleting a Network Route ...
Страница 398: ...G 4 Broadmore 1750 Release 4 6 Broadmore Command List Commands Available at the CLI Prompt ...
Страница 408: ...Glossary 10 Broadmore 1750 Release 4 6 Glossary ...