1-24
Broadmore 1750 - Release 4.6
Product Description
Alarm Power Module (APM)
Alarm Power Module (APM)
Module Type
APM
Part Number
7660-023
Slot Number
APM
Description
An APM is factory-installed in the right-most card slot
as viewed from the front. The APM provides EMI
power conditioning and over-current protection for
each of the two –48 VDC power sources. Two 7.5
amp, 60 VDC fuses are located on the bottom of the
module. A green LED is provided for each power
source to indicate power is present. Major and minor
alarms are displayed via LEDs, which are visible with
the front panel installed. An over-temperature indicator
on the front of this module is reserved for future use.
The APM is user-replaceable.
Indicators
MAJOR ALARM – lights red for major alarm
MINOR ALARM – lights amber for minor alarm
FAN FAIL – lights red when fan tray fails
OVER TEMP – (reserved for future use)
PWR A/B – lights green when power is applied to the
A or B inputs
PWR FAIL A/B – lights red when power supply A or
B fails
ALARM
PWR
A
B
PWR
FAIL
A
B
OVER
TEMP
FAN
FAIL
MINOR
ALARM
MAJOR
ALARM
7 6 6 0 - 0 2 3
Содержание Broadmore 1750
Страница 1: ...Broadmore TM 1750 USER MANUAL Part Number 770 0020 DC Product Release 4 6 January 2008 ...
Страница 24: ...xii Broadmore 1750 Release 4 6 Table of Contents ...
Страница 50: ...1 26 Broadmore 1750 Release 4 6 Product Description Alarm Power Module IOM ...
Страница 69: ...CHAPTER 3 Receipt of Product In this Chapter Receipt 3 2 Unpacking 3 2 Inspection 3 3 ...
Страница 72: ...3 4 Broadmore 1750 Release 4 6 Receipt of Product Damage Reporting ...
Страница 82: ...4 10 Broadmore 1750 Release 4 6 Chassis Installation and Grounding AC Power Supply Tray ...
Страница 114: ...6 16 Broadmore 1750 Release 4 6 Electrical Installation Software ...
Страница 188: ...7 74 Broadmore 1750 Release 4 6 Configuration Help ...
Страница 199: ...Broadmore 1750 Release 4 6 8 11 Maintenance and Troubleshooting Slot Statistics for NIM SAM Cards ...
Страница 200: ...8 12 Broadmore 1750 Release 4 6 Maintenance and Troubleshooting Slot Statistics for NIM SAM Cards ...
Страница 234: ...8 46 Broadmore 1750 Release 4 6 Maintenance and Troubleshooting Summary of Front Panel LEDs ...
Страница 244: ...9 10 Broadmore 1750 Release 4 6 Command Line Interface About Command ...
Страница 266: ...10 22 Broadmore 1750 Release 4 6 Security Management FTP Login ...
Страница 302: ...11 36 Broadmore 1750 Release 4 6 Security Management FIPS Mode sshdShow ...
Страница 311: ...Broadmore 1750 Release 4 6 11 45 Security Management FIPS Mode Logging in with SecurID Disabled ...
Страница 314: ...11 48 Broadmore 1750 Release 4 6 Security Management FIPS Mode Logging in with SecurID Enabled ...
Страница 318: ...11 52 Broadmore 1750 Release 4 6 Security Management FIPS Mode Sanitation Procedures ...
Страница 362: ...12 44 Broadmore 1750 Release 4 6 SNMP Configuration Notify Profiles ...
Страница 363: ...APPENDIX A Technical Specifications In this Appendix Broadmore 1750 Platform A 2 Broadmore Modules A 6 ...
Страница 370: ...A 8 Broadmore 1750 Release 4 6 Technical Specifications E3 Unstructured Circuit Emulation SAM ...
Страница 373: ...APPENDIX C Software Error Messages In this Appendix Overview System Errors Setup Errors ...
Страница 383: ...APPENDIX E Chassis Differences ...
Страница 386: ...E 4 Broadmore 1750 Release 4 6 Chassis Differences Software Differences ...
Страница 394: ...F 8 Broadmore 1750 Release 4 6 IPv6 Support Deleting a Network Route ...
Страница 398: ...G 4 Broadmore 1750 Release 4 6 Broadmore Command List Commands Available at the CLI Prompt ...
Страница 408: ...Glossary 10 Broadmore 1750 Release 4 6 Glossary ...