Broadmore 1750 - Release 4.6
7-35
Configuration
CPU Redundancy
Synchronizing CPU
CAUTION!
M
ODULE
REMOVAL
AND
I
NSERTION
– O
N
A
POWERED
-
UP
SYSTEM
,
WAIT
AT
LEAST
15
SECONDS
AFTER
ANY
MODULE
REMOVAL
OR
INSERTION
TO
ALLOW
THE
SYSTEM
TO
STABILIZE
. F
AILURE
TO
FOLLOW
THIS
PROCEDURE
MAY
RESULT
IN
SYSTEM
ERRORS
REQUIRING
TOTAL
SYSTEM
REBOOT
.
WHEN
INSTALLING
A
REPLACEMENT
CPU
IN
A
REDUNDANT
CPU
SYSTEM
,
DO
NOT
REBOOT
OR
POWER
DOWN
THE
SYSTEM
BEFORE
CPU
SYNCHRONIZATION
IS
COMPLETE
AS
INDICATED
BY
A
SOLID
STATUS
LIGHT
.
CPU data sync occurs automatically and should not require user intervention (see
“CPU Sync” on page
8-17
). If there is a CPU sync problem, follow the steps below
to synchronize data and operating software (SW) between the two CPUs. This
should only be done when there is file manipulation unknown to the system, such
as FTP of new files to the online CPU.
Three options are available for synchronizing CPU:
Sync CPU Data Only
,
Sync Operating SW
, and
Sync CPU Data and SW
. Synchronizing the
operating software is very time-consuming and should only be done as a last resort
when the standby CPU has no Ethernet connection to update the software by FTP.
Select
Maintenance/Diags
↵
Select
Redundancy
↵
Select
CPU
↵
Select
Sync CPU Data Only
↵
Содержание Broadmore 1750
Страница 1: ...Broadmore TM 1750 USER MANUAL Part Number 770 0020 DC Product Release 4 6 January 2008 ...
Страница 24: ...xii Broadmore 1750 Release 4 6 Table of Contents ...
Страница 50: ...1 26 Broadmore 1750 Release 4 6 Product Description Alarm Power Module IOM ...
Страница 69: ...CHAPTER 3 Receipt of Product In this Chapter Receipt 3 2 Unpacking 3 2 Inspection 3 3 ...
Страница 72: ...3 4 Broadmore 1750 Release 4 6 Receipt of Product Damage Reporting ...
Страница 82: ...4 10 Broadmore 1750 Release 4 6 Chassis Installation and Grounding AC Power Supply Tray ...
Страница 114: ...6 16 Broadmore 1750 Release 4 6 Electrical Installation Software ...
Страница 188: ...7 74 Broadmore 1750 Release 4 6 Configuration Help ...
Страница 199: ...Broadmore 1750 Release 4 6 8 11 Maintenance and Troubleshooting Slot Statistics for NIM SAM Cards ...
Страница 200: ...8 12 Broadmore 1750 Release 4 6 Maintenance and Troubleshooting Slot Statistics for NIM SAM Cards ...
Страница 234: ...8 46 Broadmore 1750 Release 4 6 Maintenance and Troubleshooting Summary of Front Panel LEDs ...
Страница 244: ...9 10 Broadmore 1750 Release 4 6 Command Line Interface About Command ...
Страница 266: ...10 22 Broadmore 1750 Release 4 6 Security Management FTP Login ...
Страница 302: ...11 36 Broadmore 1750 Release 4 6 Security Management FIPS Mode sshdShow ...
Страница 311: ...Broadmore 1750 Release 4 6 11 45 Security Management FIPS Mode Logging in with SecurID Disabled ...
Страница 314: ...11 48 Broadmore 1750 Release 4 6 Security Management FIPS Mode Logging in with SecurID Enabled ...
Страница 318: ...11 52 Broadmore 1750 Release 4 6 Security Management FIPS Mode Sanitation Procedures ...
Страница 362: ...12 44 Broadmore 1750 Release 4 6 SNMP Configuration Notify Profiles ...
Страница 363: ...APPENDIX A Technical Specifications In this Appendix Broadmore 1750 Platform A 2 Broadmore Modules A 6 ...
Страница 370: ...A 8 Broadmore 1750 Release 4 6 Technical Specifications E3 Unstructured Circuit Emulation SAM ...
Страница 373: ...APPENDIX C Software Error Messages In this Appendix Overview System Errors Setup Errors ...
Страница 383: ...APPENDIX E Chassis Differences ...
Страница 386: ...E 4 Broadmore 1750 Release 4 6 Chassis Differences Software Differences ...
Страница 394: ...F 8 Broadmore 1750 Release 4 6 IPv6 Support Deleting a Network Route ...
Страница 398: ...G 4 Broadmore 1750 Release 4 6 Broadmore Command List Commands Available at the CLI Prompt ...
Страница 408: ...Glossary 10 Broadmore 1750 Release 4 6 Glossary ...