Broadmore 1750 - Release 4.6
5-9
Module and Fan Installation
NIM Installation
NIM Installation
1. If a Building Integrated Timing Supply (BITS) clock will be used, an
impedance matching adjustment may be required before installing an OC-12
NIMs. BITS impedance matching jumpers are located on the NIM component
side below the midplane connectors. They are labeled
JMP1
,
JMP2
,
JMP3
,
and
JMP4
. The following settings are available.
JMP3, JMP4 in (default)
100 ohms
JMP1, JMP2, JMP3, JMP4 in
75 ohms
All jumpers out
No termination
BITS input is provided to the RJ48C BITS connector on the corresponding
NIM IOM (see
“BITS Interface Connections” on page
6-7
).
NOTE:
OC-12 NIMs go in slots A and B. (Both optical NIMs must be
identical.) The NIM in slot B is the Working unit and the NIM in slot A is the
Protection unit.
2. Place the Working NIM in slot B from the front so that it slides smoothly in the
top and bottom card guides and the card connector aligns with the midplane
connector.
3. Firmly press the NIM into the chassis until the connectors seat against each
other completely. Use pressure simultaneously at the top and bottom of the
NIM to ensure a proper fit to the midplane.
4. Secure the screws on the top and bottom of the module, being careful not to
over-tighten.
5. For redundant NIMs, repeat this process to install the Protection NIM in slot A.
Содержание Broadmore 1750
Страница 1: ...Broadmore TM 1750 USER MANUAL Part Number 770 0020 DC Product Release 4 6 January 2008 ...
Страница 24: ...xii Broadmore 1750 Release 4 6 Table of Contents ...
Страница 50: ...1 26 Broadmore 1750 Release 4 6 Product Description Alarm Power Module IOM ...
Страница 69: ...CHAPTER 3 Receipt of Product In this Chapter Receipt 3 2 Unpacking 3 2 Inspection 3 3 ...
Страница 72: ...3 4 Broadmore 1750 Release 4 6 Receipt of Product Damage Reporting ...
Страница 82: ...4 10 Broadmore 1750 Release 4 6 Chassis Installation and Grounding AC Power Supply Tray ...
Страница 114: ...6 16 Broadmore 1750 Release 4 6 Electrical Installation Software ...
Страница 188: ...7 74 Broadmore 1750 Release 4 6 Configuration Help ...
Страница 199: ...Broadmore 1750 Release 4 6 8 11 Maintenance and Troubleshooting Slot Statistics for NIM SAM Cards ...
Страница 200: ...8 12 Broadmore 1750 Release 4 6 Maintenance and Troubleshooting Slot Statistics for NIM SAM Cards ...
Страница 234: ...8 46 Broadmore 1750 Release 4 6 Maintenance and Troubleshooting Summary of Front Panel LEDs ...
Страница 244: ...9 10 Broadmore 1750 Release 4 6 Command Line Interface About Command ...
Страница 266: ...10 22 Broadmore 1750 Release 4 6 Security Management FTP Login ...
Страница 302: ...11 36 Broadmore 1750 Release 4 6 Security Management FIPS Mode sshdShow ...
Страница 311: ...Broadmore 1750 Release 4 6 11 45 Security Management FIPS Mode Logging in with SecurID Disabled ...
Страница 314: ...11 48 Broadmore 1750 Release 4 6 Security Management FIPS Mode Logging in with SecurID Enabled ...
Страница 318: ...11 52 Broadmore 1750 Release 4 6 Security Management FIPS Mode Sanitation Procedures ...
Страница 362: ...12 44 Broadmore 1750 Release 4 6 SNMP Configuration Notify Profiles ...
Страница 363: ...APPENDIX A Technical Specifications In this Appendix Broadmore 1750 Platform A 2 Broadmore Modules A 6 ...
Страница 370: ...A 8 Broadmore 1750 Release 4 6 Technical Specifications E3 Unstructured Circuit Emulation SAM ...
Страница 373: ...APPENDIX C Software Error Messages In this Appendix Overview System Errors Setup Errors ...
Страница 383: ...APPENDIX E Chassis Differences ...
Страница 386: ...E 4 Broadmore 1750 Release 4 6 Chassis Differences Software Differences ...
Страница 394: ...F 8 Broadmore 1750 Release 4 6 IPv6 Support Deleting a Network Route ...
Страница 398: ...G 4 Broadmore 1750 Release 4 6 Broadmore Command List Commands Available at the CLI Prompt ...
Страница 408: ...Glossary 10 Broadmore 1750 Release 4 6 Glossary ...