![Carmanah G Series Скачать руководство пользователя страница 85](http://html.mh-extra.com/html/carmanah/g-series/g-series_user-manual_2559190085.webp)
Carmanah Technologies Corp. | 250 Bay St, Victoria, BC V9A 3K5, Canada | 1-877-722-8877 |
85
G SERIES USER MANUAL
6.0 ENERGY MANAGEMENT SYSTEM PROGRAMMING
6.4 R829-G Programming
To configure the EMS as an R829:
Set
fla5
(Flash Pattern) as desired
Set
inpt
(Input Type) to
NO
(normally open)
Set
temp
(LED temperature) to either
red
or
yel
to match the circular beacon color
Set
cal
to
ON
unless it is a Slave in a group of wireless R829s, in which case set
cal
to
off
Set
RF
(Radio Enable) to
ON
if the system is in a group of wireless R829s. Otherwise, set
RF
to
OFF
6.5 R247-G Programming
To configure the EMS as an R247:
Set
fla5
(Flash Pattern) as desired
Set
inpt
(Input Type) to
NC
(normally closed)
Set
temp
(LED temperature) to either
red
or
yel
to match the circular beacon color
Set
cal
(Internal Calendar) to
off
Set
RF
(Radio Enable) to
OFF