6.0 ENERGY MANAGEMENT SYSTEM PROGRAMMING
LED Fixture Test
The LED Fixture Test function causes the fixture(s) to flash independently of an activation input from a physical
pushbutton, time switch, internal calendar or external control. The test will activate the fixture for 5 seconds. “Test”
is a good way to determine whether a problem is caused by the fixtures.
Installers can do this from the EMS without having to climb down to the pushbutton or override box to test.
Built-In Self-Test (BIST)
The Built-In Self-Test (BIST) runs a self-test on the system. BIST results are used for troubleshooting the system.
After the BIST has been started by selecting “Yes”, the display will flash
Test
for the duration of the test and
will then display hexadecimal information that can represent one or more issues. The BIST can be used for
troubleshooting remotely with Carmanah Customer Service.
for BIST Error Code hexadecimal interpretation table.
The BIST may report an ambient brightness sensor error (0080) because it is expecting a bright
light that tests the sensor during manufacturing. Shining a flashlight on the ambient brightness
sensor during the test or running the BIST on a sunny day should result in no error being
generated.
The BIST will report a charger error (4000) if performed at night or on AC powered systems.
T
he BIST c
hecks that temperature is between 15° C and 35° C. With installation sites frequently
having temperatures outside of this range, a
temperature check
code
(0002)
will often be
generated while there is no real issue with temperature.