G SERIES USER MANUAL
2.0 INTRODUCTION
2.13 Multiple Steady-On Loads
The “stdY” flash code allows the use of steady-on loads. Only one LED bank is active when using this flash
pattern and multiple loads must only be connected in series. The combined forward voltage of the loads must be
less than 30 Volts, but different load types may be mixed in this configuration and will all receive the same
current.
Flash code stdY is only available with EMS firmware 1.1.3.0 or later. See Firmware Version in
for instructions on how to check the EMS firmware version.
Custom harnessing (not supplied by Carmanah) is required to wire loads in series.
Load
1
Load
2
LED B1
Harness
Customer supplied wiring
+
+
-
-