5.0 INSTALLATION OF OPTIONAL ACCESSORIES
5.10 Campbell Guardian Audible Pushbutton Kit Installation
The Campbell Guardian audible pushbutton kit includes a pushbutton harness (16ft, 36ft, or 75ft) prewired to the
G Series EMS (as shown below), along with the Guardian audible pushbutton and an associated sign. Please
consult Campbell’s installation documentation for more information.
The Digital Output on the EMS must be set to ALL when used with the Guardian pushbutton on
standard systems.
For systems with no installed fixture, the Digital Output must be set to nLED. This function
requires the EMS to have firmware version 1.1.5.0 or newer. See Firmware Version in Section
6.1 for instructions on how to check the EMS firmware version. Contact Carmanah for instructions
if adding an audible pushbutton to an older system.
Campbell
Terminal
Wire Color Terminal Block
Connection
Function
Field terminal
Orange
INPT+
1 of 2 pushbutton inputs to EMS from Guardian
Field terminal
Brown
INPT−
2 of 2 pushbutton inputs to EMS from Guardian
+12VDC
Red
DC+
Positive side of 12-volt power supply for Guardian
-GND
Black
DC−
Negative side of 12-volt power supply for Guardian
W (Walk)
Yellow
OUT2
Guardian sense line for triggering recorded message
when fixture flashing is detected
Not Used
Blue/Black
DC-
Not used, apply tape to wire end or trim at jacket exit
DW (Don’t Walk)
Not used