G SERIES USER MANUAL
2.0 INTRODUCTION
2.12 Alternating Three Beacon Setup
Flash code 0.5A3 allows a single EMS to operate 3 beacons in an alternating 0.5 sec on, 0.5 sec off configuration
while maintaining the same intensity across all 3 beacons.
When selected, the second LED bank will provide only half of the current of first LED bank so that beacons 1 and
3, connected to the harnesses labeled “LED B1”, and beacon 2, connected to harness labeled “LED B2”, will have
the same brightness.
See
for details on LED banks and beacon connections.
Beacons 1 and 3 flash in unison but face in the opposite direction, so a driver will either see Beacon 3 only or see
Beacons 1 and 2 alternate at the same intensity.
Flash code 0.5A3 is only available with EMS firmware 1.1.3.0 or later. See Firmware Version in
for instructions on how to check the EMS firmware version.
The beacons must be connected and installed as detailed here to obtain the desired result, see
(see
Intensity
LED loads driven from one EMS must have the same operating voltage. Do not mix different
sizes, colors, or types of LED loads connected to the same EMS. Use a dual-EMS G Series or
additional E/F systems to drive different types of LED loads.
Beacon 1
Beacon 2
Beacon 3
Beacon 1
Beacon 2
Beacon 3
0.0 - 0.5 sec
0.5 - 1.0 sec