DISxRSE Car Park Display
– Configuration manual
16
Electrical installation
Risk of electrocution
▪
Electrical installation must ONLY be performed by a qualified
electrician.
▪
Wear appropriate protective clothing / equipment during any maintenance
activity.
Things to know
In this chapter, you can find information about the electrical wiring related to the SBP2DI4854
interface and the power supply installation.
Size the power supply unit
The display must be connected to a SBP2DI48524 display interface that is powered by 24 V dc
nominal.
•
The power consumption depends on the model.
•
An SBP2DI48524 interface can be connected to one display only
The table below shows the devices with the relevant power consumption that has to be
considered to sizing the power supply unit:
Part number
Max. rated operational power
DISARSE
32 W
DISBRSE
53 W
DISCRSE
95 W