background image

AREA

Tells where hazards

may occur.

HAZARD

Tells what the hazard is.

SAFEGUARDS

Tells how to avoid the hazard.

High voltage equipment is 

utilized in the process.  Arcing 

in  the  vicinity  of  flammable  or 

combustible  materials  may 

occur. Personnel are exposed 

to high voltage during operation 

and maintenance.

Protection against inadvertent 

arcing that may cause a fire or 

explosion is lost if safety circuits 

are disabled during operation.

Frequent  power  supply  shut-

down  indicates  a  problem  in 

the system which requires 

correction.

An electrical arc can ignite 

coating materials and cause a 

fire or explosion.

Unless  specifically  approved  for  use  in  hazardous 

locations, the power supply, control cabinet, and all 

other electrical equipment must be located outside 

Class I or II, Division 1 and 2 hazardous areas in 

accordance with NFPA-33 and EN 50176.

 

Turn the power supply OFF before working on the 

equipment.

 

Test only in areas free of flammable or combustible 

material.

 

Testing may require high voltage to be on, but only 

as instructed.

 

Production  should  never  be  done  with  the  safety 

circuits disabled.

 

Before turning the high voltage on, make sure no 

objects are within the sparking distance.

Electrical Discharge

Electrical 

Equipment

Certain materials may be 

harmful if inhaled, or if there is 

contact with the skin.

Follow the requirements of the Safety Data Sheet 

supplied by coating material manufacturer.

Adequate exhaust must be provided to keep the air 

free of accumulations of toxic materials.

Use a mask or respirator whenever there is a chance 

of  inhaling  sprayed  materials.  The  mask  must  be 

compatible with the material being sprayed and its 

concentration.  Equipment  must  be  as  prescribed 

by an industrial hygienist or safety expert, and be 

NIOSH approved.

Chemical Hazard

Toxic Substances

Spray applicators require that aluminum inlet fittings 

be replaced with stainless steel. 

Aluminum is widely used in other spray application 

equipment  -  such  as  material  pumps,  regulators, 

triggering  valves,  etc.  Halogenated  hydrocarbon 

solvents  must  never  be  used  with  aluminum 

equipment  during  spraying,  flushing,  or  cleaning.  

Read  the  label  or  data  sheet  for  the  material  you 

intend to spray. If in doubt as to whether or not a 

coating or cleaning material is compatible, contact 

your coating supplier. Any other type of solvent may 

be used with aluminum equipment.

Halogenated hydrocarbon 

solvents for example: 

methylene chloride and 

1,1,1,-Trichloroethane are not 

chemically compatible with the 

aluminum that might be used 

in many system components.  

The chemical reaction 

caused by these solvents 

reacting with aluminum can 

become violent and lead to an 

equipment explosion.

Explosion Hazard —

Incompatible Materials

Spray Area

LN-9418-01-R0  (08/2018)

7 / 17

www.carlisleft.com

SAFETY

EN

Содержание Ransburg RCS2 A14084-00

Страница 1: ...TIONS and all instructions in this manual Keep this Service Manual for future reference Model A14084 00 RCS2 Interface with Ethernet IP Card RCS2 Ethernet IP Implicit Communications Programmer s Manua...

Страница 2: ...RCS2 Ethernet IP Implicit Output Definitions Table 10 System Status Flags World Table 11 Gun Status Flags World Table 11 System Outputs 11 Gun Outputs Status Bits 12 Gun Outputs Valve 12 INPUT COMMAND...

Страница 3: ...teminstallationdrawingsandappropriateRansburg equipment manuals to reconcile such differences Careful study and continued use of this manual will provide a betterunderstandingoftheequipmentandprocess...

Страница 4: ...nce Spray booth ventilation must be kept at the rates required by NFPA 33 OSHA country and local codes In addition ventilation must be maintained during cleaning operations using flammable or combusti...

Страница 5: ...st inadvertent arcing that is capable of causing fire or explosion is lost if the current overload sensitivity is not properly set Frequent power supply shutdown indicates a problem in the system whic...

Страница 6: ...ot be wearing or carrying any ungrounded metal objects When using an electrostatic handgun operators must assure contact with the handle of the applicator via conductive gloves or gloves with the palm...

Страница 7: ...re is contact with the skin Follow the requirements of the Safety Data Sheet supplied by coating material manufacturer Adequate exhaust must be provided to keep the air free of accumulations of toxic...

Страница 8: ...16 bit words of output The Assembly instances are defined for the controller as follows NOTE When defining the IO Instances to the host system specify the input object of the controller as the output...

Страница 9: ...RCS2 ETHERNET I P CONFIGURATION ALLEN BRADLEY CONTROL LOGIX LN 9418 01 R0 08 2018 9 17 www carlisleft com EN INTERFACE...

Страница 10: ...lags see table 1 2 below 4 Gun 2 Actual Flow Rate cc s min 5 Gun 3 Status Flags Flags see table 1 2 below 6 Gun 3 Actual Flow Rate cc s min 7 Gun 4 Status Flags Flags see table 1 2 below 8 Gun 4 Actua...

Страница 11: ...can be configured to cause the horn to sound when it faults independent of each other Note that the horn must be enabled on the CONFIG SYSTEM screen or the horn will not sound for gun faults regardle...

Страница 12: ...umber has been loaded and the gun has been placed in Run Mode or the Volume Fill Mode This bit is false if a fault occurs if it is Halted or in the Ready state Spray Shutdown This bit is true if a fau...

Страница 13: ...ith non zero values If enabled and non zero the EIP setpoint value will be used The next priority will be given to an FMS forced setpoint value The third priority will be the Analog input reading Fina...

Страница 14: ...olume Fill 11 Push Out 12 13 14 15 GUN INPUTS COMMAND BITS Fast Fill Type of Input Gun Type of Signal Pulsed Triggered on rising edge The gun must be in Run Mode or Volume Fill Mode prior to initiatin...

Страница 15: ...Mode the discrete output labeled Gun Run will be energized Halt Fault Reset Type of Input Gun Type of Signal Pulsed Triggered on rising edge This input bit takes a configured gun that is in Run Mode...

Страница 16: ...n in Pushout Mode When initiated the RCS 2 will immediately turn off the catalyst pump and speed up the resin pump to maintain the target flow rate that was being sprayed prior to the initiation of pu...

Страница 17: ...chnologies is a global leader in innovative finishing technologies Carlisle Fluid Technologies reserves the right to modify equipment specifications without prior notice DeVilbiss Ransburg MS BGK and...

Отзывы: