OUTPUT STATUS DATA
(TARGET TO ORIGINATOR ASSEMBLY)
The following section describes the structure and
content of the Implicit status data output from the RCS2
Interface-EIP card. All data fields will be continuously
transmitted whether or not the Gun is currently
configured in the system.
Data Contained
Word #
Units
0
System - Status Flags
Flags - see table 1.1 below
1
Gun 1 - Status Flags
Flags - see table 1.2 below
2
Gun 1 – Actual Flow Rate
cc’s/min
3
Gun 2 - Status Flags
Flags - see table 1.2 below
4
Gun 2 – Actual Flow Rate
cc’s/min
5
Gun 3 - Status Flags
Flags - see table 1.2 below
6
Gun 3 – Actual Flow Rate
cc’s/min
7
Gun 4 - Status Flags
Flags - see table 1.2 below
8
Gun 4 – Actual Flow Rate
cc’s/min
9
Gun 5 - Status Flags
Flags - see table 1.2 below
10
Gun 5 – Actual Flow Rate
cc’s/min
11
Gun 6 - Status Flags
Flags - see table 1.2 below
12
Gun 6 – Actual Flow Rate
cc’s/min
13
Gun 7 - Status Flags
Flags - see table 1.2 below
14
Gun 7 – Actual Flow Rate
cc’s/min
15
Gun 8 - Status Flags
Flags - see table 1.2 below
16
Gun 8 – Actual Flow Rate
cc’s/min
TABLE 1 - RCS2 ETHERNET/IP IMPLICIT OUTPUT DEFINITIONS
LN-9418-01-R0 (08/2018)
10 / 17
www.carlisleft.com
OUTPUT
EN