Volume Fill with Fast Fill Mode:

It is possible to Volume Fill and Fast Fill simultaneously.  If 

the gun is put into Volume Fill Mode, and then the Fast Fill 

input is made high momentarily, the unit will run in Fast 

Fill Mode until the volume programmed in for Fill Volume 

is dispensed. At that time, the gun will be automatically 

halted by the software.  This happens regardless of the 

condition of the gun trigger inputs so make sure the 

applicator is triggered or an overpressure fault may occur.  

When  it  is  desirable  to  run  both  modes  in  parallel,  it  is 

important to watch the Run output bit to ensure the unit 

has in fact gone into Volume Fill Mode prior to sending 

the Fast Fill bit.

Pushout

Type of input: Gun

Type of signal: Maintained

When this input is made high, it puts the gun in “Pushout 

Mode”.  When initiated, the RCS-2 will immediately turn 

off the catalyst pump and speed up the resin pump to 

maintain the target flow rate that was being sprayed prior 

to the initiation of pushout mode.  (Note that this pushout 

bit  must  be  maintained.)    The  RCS-2  will  continue  to 

deliver fluid out of the first dual purge side until the volume 

programmed in for Mixed Volume has been sprayed and 

then that gun will automatically be halted by the software 

(taken out of Run Mode).  This state will be recognized by 

the PLC or robot when the Run output bit from the RCS-2 

goes false.  For more information on using this function, 

refer to the Operator’s Manual.

GUN INPUTS (VALUE)

Flow Setpoint

Type of input: Gun

Type of signal: Maintained

The allowable range of values for this parameter is any 

integer from 0 cc’s/min to 10,000 cc’s/min. This is the 

target flow rate for the output of the fluid panel associated 

with this gun.

LN-9418-01-R0  (08/2018)

16 / 17

www.carlisleft.com

EN

INPUT

Содержание Ransburg RCS2 A14084-00

Страница 1: ...TIONS and all instructions in this manual Keep this Service Manual for future reference Model A14084 00 RCS2 Interface with Ethernet IP Card RCS2 Ethernet IP Implicit Communications Programmer s Manua...

Страница 2: ...RCS2 Ethernet IP Implicit Output Definitions Table 10 System Status Flags World Table 11 Gun Status Flags World Table 11 System Outputs 11 Gun Outputs Status Bits 12 Gun Outputs Valve 12 INPUT COMMAND...

Страница 3: ...teminstallationdrawingsandappropriateRansburg equipment manuals to reconcile such differences Careful study and continued use of this manual will provide a betterunderstandingoftheequipmentandprocess...

Страница 4: ...nce Spray booth ventilation must be kept at the rates required by NFPA 33 OSHA country and local codes In addition ventilation must be maintained during cleaning operations using flammable or combusti...

Страница 5: ...st inadvertent arcing that is capable of causing fire or explosion is lost if the current overload sensitivity is not properly set Frequent power supply shutdown indicates a problem in the system whic...

Страница 6: ...ot be wearing or carrying any ungrounded metal objects When using an electrostatic handgun operators must assure contact with the handle of the applicator via conductive gloves or gloves with the palm...

Страница 7: ...re is contact with the skin Follow the requirements of the Safety Data Sheet supplied by coating material manufacturer Adequate exhaust must be provided to keep the air free of accumulations of toxic...

Страница 8: ...16 bit words of output The Assembly instances are defined for the controller as follows NOTE When defining the IO Instances to the host system specify the input object of the controller as the output...

Страница 9: ...RCS2 ETHERNET I P CONFIGURATION ALLEN BRADLEY CONTROL LOGIX LN 9418 01 R0 08 2018 9 17 www carlisleft com EN INTERFACE...

Страница 10: ...lags see table 1 2 below 4 Gun 2 Actual Flow Rate cc s min 5 Gun 3 Status Flags Flags see table 1 2 below 6 Gun 3 Actual Flow Rate cc s min 7 Gun 4 Status Flags Flags see table 1 2 below 8 Gun 4 Actua...

Страница 11: ...can be configured to cause the horn to sound when it faults independent of each other Note that the horn must be enabled on the CONFIG SYSTEM screen or the horn will not sound for gun faults regardle...

Страница 12: ...umber has been loaded and the gun has been placed in Run Mode or the Volume Fill Mode This bit is false if a fault occurs if it is Halted or in the Ready state Spray Shutdown This bit is true if a fau...

Страница 13: ...ith non zero values If enabled and non zero the EIP setpoint value will be used The next priority will be given to an FMS forced setpoint value The third priority will be the Analog input reading Fina...

Страница 14: ...olume Fill 11 Push Out 12 13 14 15 GUN INPUTS COMMAND BITS Fast Fill Type of Input Gun Type of Signal Pulsed Triggered on rising edge The gun must be in Run Mode or Volume Fill Mode prior to initiatin...

Страница 15: ...Mode the discrete output labeled Gun Run will be energized Halt Fault Reset Type of Input Gun Type of Signal Pulsed Triggered on rising edge This input bit takes a configured gun that is in Run Mode...

Страница 16: ...n in Pushout Mode When initiated the RCS 2 will immediately turn off the catalyst pump and speed up the resin pump to maintain the target flow rate that was being sprayed prior to the initiation of pu...

Страница 17: ...chnologies is a global leader in innovative finishing technologies Carlisle Fluid Technologies reserves the right to modify equipment specifications without prior notice DeVilbiss Ransburg MS BGK and...

Отзывы: