background image

System – Command Flags 

(Future)

Gun 1 - Command Flags 

Flags - see table 2.1 below

Gun 1 – Target Flow Rate  

cc’s/min

Gun 2 - Command Flags 

Flags - see table 2.1 below

Gun 2 – Target Flow Rate  

cc’s/min

Gun 3 - Command Flags 

Flags - see table 2.1 below

Gun 3 – Target Flow Rate  

cc’s/min

Gun 4 - Command Flags 

Flags - see table 2.1 below

Gun 4 – Target Flow Rate  

cc’s/min

Gun 5 - Command Flags 

Flags - see table 2.1 below

10 

Gun 5 – Target Flow Rate  

cc’s/min

11 

Gun 6 - Command Flags 

Flags - see table 2.1 below

12 

Gun 6 – Target Flow Rate  

cc’s/min

13 

Gun 7 - Command Flags 

Flags - see table 2.1 below

14 

Gun 7 – Target Flow Rate  

cc’s/min

15 

Gun 8 - Command Flags 

Flags - see table 2.1 below

16 

Gun 8 – Target Flow Rate  

cc’s/min

Data Contained

Word #

Units

TABLE 2 - RCS2 ETHERNET/IP IMPLICIT INPUT DEFINITIONS

Gun Command Flags

Bit #

TABLE 2.1 - GUN COMMAND

FLAGS WORD

Fast Fill

Channel Fill (Master)

Feather Set

3 Run

Halt/Fault Reset

Trigger 1

Channel Fill (Slave)

Trigger 2

Trigger 3

Trigger 4

10 

Volume Fill

11 

Push Out

12 
13 
14 
15

GUN INPUTS (COMMAND BITS)

Fast Fill

Type of Input: Gun

Type of Signal: Pulsed, Triggered on rising edge

The gun must be in Run Mode or Volume Fill Mode prior 

to initiating this Mode or the RCS-2 controller will ignore 

the command.  If the gun is configured as a single channel 

gun and this signal is pulsed, the gun will cause the pump 

to run at its maximum speed (typically 150 RPM) until the 

halt signal is pulsed.  (Note that it is not necessary to have 

the trigger signal energized, flow starts immediately.)  If 

the  gun  is  configured  as  a  two-channel  gun,  and  this 

input is pulsed, the pumps will run at the maximum speed 

possible  while  maintaining  the  target  ratio.  That  is,  the 

software will determine which of the two pumps can be 

run at its maximum speed and run the opposite channel 

at whatever speed necessary to insure the proper ratio of 

component A to component B. The software determines 

this  based  on  the  programmed  pump  sizes  and  the 

programmed ratio.  Pulsing the Halt/Reset input takes the 

gun out of Fast Fill Mode.  (Note also paragraph below 

describing using Fast Fill with Volume Fill.)

LN-9418-01-R0  (08/2018)

14 / 17

www.carlisleft.com

EN

INPUT

Содержание Ransburg RCS2 A14084-00

Страница 1: ...TIONS and all instructions in this manual Keep this Service Manual for future reference Model A14084 00 RCS2 Interface with Ethernet IP Card RCS2 Ethernet IP Implicit Communications Programmer s Manua...

Страница 2: ...RCS2 Ethernet IP Implicit Output Definitions Table 10 System Status Flags World Table 11 Gun Status Flags World Table 11 System Outputs 11 Gun Outputs Status Bits 12 Gun Outputs Valve 12 INPUT COMMAND...

Страница 3: ...teminstallationdrawingsandappropriateRansburg equipment manuals to reconcile such differences Careful study and continued use of this manual will provide a betterunderstandingoftheequipmentandprocess...

Страница 4: ...nce Spray booth ventilation must be kept at the rates required by NFPA 33 OSHA country and local codes In addition ventilation must be maintained during cleaning operations using flammable or combusti...

Страница 5: ...st inadvertent arcing that is capable of causing fire or explosion is lost if the current overload sensitivity is not properly set Frequent power supply shutdown indicates a problem in the system whic...

Страница 6: ...ot be wearing or carrying any ungrounded metal objects When using an electrostatic handgun operators must assure contact with the handle of the applicator via conductive gloves or gloves with the palm...

Страница 7: ...re is contact with the skin Follow the requirements of the Safety Data Sheet supplied by coating material manufacturer Adequate exhaust must be provided to keep the air free of accumulations of toxic...

Страница 8: ...16 bit words of output The Assembly instances are defined for the controller as follows NOTE When defining the IO Instances to the host system specify the input object of the controller as the output...

Страница 9: ...RCS2 ETHERNET I P CONFIGURATION ALLEN BRADLEY CONTROL LOGIX LN 9418 01 R0 08 2018 9 17 www carlisleft com EN INTERFACE...

Страница 10: ...lags see table 1 2 below 4 Gun 2 Actual Flow Rate cc s min 5 Gun 3 Status Flags Flags see table 1 2 below 6 Gun 3 Actual Flow Rate cc s min 7 Gun 4 Status Flags Flags see table 1 2 below 8 Gun 4 Actua...

Страница 11: ...can be configured to cause the horn to sound when it faults independent of each other Note that the horn must be enabled on the CONFIG SYSTEM screen or the horn will not sound for gun faults regardle...

Страница 12: ...umber has been loaded and the gun has been placed in Run Mode or the Volume Fill Mode This bit is false if a fault occurs if it is Halted or in the Ready state Spray Shutdown This bit is true if a fau...

Страница 13: ...ith non zero values If enabled and non zero the EIP setpoint value will be used The next priority will be given to an FMS forced setpoint value The third priority will be the Analog input reading Fina...

Страница 14: ...olume Fill 11 Push Out 12 13 14 15 GUN INPUTS COMMAND BITS Fast Fill Type of Input Gun Type of Signal Pulsed Triggered on rising edge The gun must be in Run Mode or Volume Fill Mode prior to initiatin...

Страница 15: ...Mode the discrete output labeled Gun Run will be energized Halt Fault Reset Type of Input Gun Type of Signal Pulsed Triggered on rising edge This input bit takes a configured gun that is in Run Mode...

Страница 16: ...n in Pushout Mode When initiated the RCS 2 will immediately turn off the catalyst pump and speed up the resin pump to maintain the target flow rate that was being sprayed prior to the initiation of pu...

Страница 17: ...chnologies is a global leader in innovative finishing technologies Carlisle Fluid Technologies reserves the right to modify equipment specifications without prior notice DeVilbiss Ransburg MS BGK and...

Отзывы: