RAYTEK PYROMETER REPLACEMENT CALIBRATION VERIFICATION ON
OVERHEAD OR PORTABLE REPAIR ARM USING A HAND HELD PYROMETER
(Raytek MID Pyrometer with BGK Temperature Controller ONLY)
Purpose:
This procedure is to be completed to verify the temperature display is correct on the
BGK temperature controller. Then the BGK “
Auto-Cure
” series repair arms will heat the
painted spot repair to the correct temperatures to achieve the proper cure of the paint.
Equipment Required:
Hand-held Infrared pyrometer in
good working order with a current calibration
label. Pyrometer with laser aiming is preferred.
A good condition scrap painted door, fender, or test panel on which to perform
the calibration is required. (White or light color is preferred).
A #1 Phillips screwdriver.
RAYMID10LT Pyrometer Sensor manufactured by Raytek has been discontinued. It has
been replaced by model number RAYMI3D10LTS. This Change affects the following
Autocure units AC3, AC5, AC6 & AC7, and AC8.