4.  Check System • Start-up Burner/Appliance

Inspect/check system

Before starting the burner and appliance, verify the system has been installed 
as directed by this manual and the appliance instructions.

Check gas piping for leaks

  Disconnect the burner from the gas supply line if gas line 

test pressure will exceed 14 inches w.c. Exposing the burner 
combination gas valve to pressure higher than 14 inches w.c. 
can damage the valve seat, resulting in potentially unsafe 
operation.

You can usually test the gas piping by allowing the line to fill with gas to 
main regulator outlet pressure. 
1.  Shut off gas flow to all appliances connected to the meter.

2.  If test pressure will be less than 14 inches w.c., turn the burner combi-

nation gas valve knob to OFF. 

If test pressure will be higher than 14 

inches, disconnect the burner from the gas line

 by shutting off the 

main manual gas valve installed near the burner (per Figure 5, page 9) 
and disconnecting the ground joint union. See warning above.

3.  Watch the gas meter dial. For a one half cubic foot per revolution dial, 

there should be no movement of the dial for at least 5 minutes. For 
larger volumes per revolution, increase this time proportionately.

4.  If you detect a gas leak, locate the leak with a soap suds mixture and 

repair it. Then test the system for leaks again.

  Do not test for leaks with an open flame. And do not use 

oxygen as  a  test  gas.  Either  of  these  could  cause an 
explosion,  resulting  in  severe  personal  injury,  death  or 
substantial property damage.

Bleed gas line

Purge all air from the gas line. Purge to outside of the building, NEVER into 
the appliance or burner.

Leak test near-burner gas piping

If piping near burner has not already been pressure tested, open main 
manual gas valve on supply to burner and smell around area for any signs of 
gas. Apply a soap suds mixture to all gas piping joints near burner and check 
for any leaks. If any leaks appear, repair before proceeding and retest.

Set air throttle

1.  See Figure 8. Loosen air throttle locking nut.
2.  Rotate the air throttle plate clockwise to the closed position.
3.  Check the air throttle indicator. The “0” position of the indicator should 

be even with the end of the air inlet tube. If not, bend the arm slightly 
until the indicator reads zero.

4.  Rotate air throttle until indicator points to setting given in Figure 4, 

page 8.

5.  Tighten air throttle locking nut.

Figure 8

  Air throttle adjustment

  Do not start the burner if you smell gas or if there may be gas 

present in the appliance combustion chamber, heat exchanger 
or the vent system. An explosion could occur,  causing severe 
personal injury, death or substantial property damage. 

  During initial start-up, you must be constantly alert for 

emergency conditions such as fuel leaks, electrical malfunc-
tions, etc. Familiarize yourself with the location of manual 
shutoff valves and switches so you can quickly use them if 
needed.

  If the burner fails to ignite, NEVER attempt to manually bypass 

the normal sequence of the control, which provides purging 
of the combustion chamber. 

6.  The Figure 4 setting will probably be satisfactory without change. If the 

combustion test indicates a need for more or less air, however, you will 
have to adjust the throttle accordingly.

Check burner and Honeywell S89C control

Inspect burner thoroughly. Verify all components are secure and burner 
is in good condition. Verify all wiring is in place and all components are 
secure and in position.

Verify flame failure lockout of Honeywell control

1.  Install a hose barb fitting in the combination gas valve outlet pressure tap 

and connect with a hose to a U-tube manometer.

2.  Close the main manual gas valve and turn the combination gas valve knob 

to ON.

3.  Turn on power to appliance and set appliance limit(s) to call for heat.
4.  Burner motor will start. The Honeywell S89C control will run the blower for 

34 seconds (pre-purge and ignitor warm-up). Then the combination gas 
valve will open and the “Valve on” light will light. (The manometer should 
show almost no pressure, because the main manual gas valve is closed.) 

5.  After 6 seconds, the S89C will lockout. The ignitor will shut off and the gas 

valve will close. Turn off power or interrupt thermostat circuit for 45 seconds. 
The control should reset. Turn off power and set controls to stop call for 
heat.

6.  If lockout does not occur, replace the S89C control.

Содержание G3B

Страница 1: ...servicer Except where specifi cally stated otherwise this manual must be used only by a qualified service technician In the state of MA this product must be installed by a licensed plumber or gas fit...

Страница 2: ...l property damage Before leaving the site after startup or service review the User s information manual with the user Make the user aware of all potential hazards and perform the training outlined bel...

Страница 3: ...ith integral gas pressure regulation set for 3 w c outlet pressure 10 Control panel 11 Terminal strip 12 Primary control Honeywell Model S89C primary control for use with flame rectification 13 Contro...

Страница 4: ...less steel liner to vent the flue products A defective vent system could result in severe personal injury death or substantial property damage Vent chimney sizing Follow all local codes when sizing th...

Страница 5: ...ion for louvers of 1 square inch per 1 000 Btuh of all appliances in the space If the building construc tion is unusually tight see National Fuel Gas Code or CSA B149 1 or 2 for definition you will ne...

Страница 6: ...around the burner air tube is more than wrap the burner air tube with minimum 2300 F rated ceramic fiber blanket to seal off the gap Notice that the flameholder may extend slightly into chamber as sho...

Страница 7: ...ng these items Avoid breathing dust and avoid contact with skin or eyes Wear long sleeved loose fitting clothing gloves and eye protection Use a NIOSH N95 certified respirator This respirator meets re...

Страница 8: ...eding Failure to do so could result in severe personal injury death or substantial property damage 3 Loosen Allen screws securing gas line to burner gas connection 4 Remove combination gas valve item...

Страница 9: ...connection as shown in Figure 5 4 If the burner is installed inside the appliance jacket install the main manual gas valve and sediment trap external to the jacket 5 Size piping or verify size usingT...

Страница 10: ...ersonal injuiry death or substantial property damage Figure 6 Ladder wiring diagram Electrically ground burner The burner must be grounded in accordance with local codes or in the absence of local cod...

Страница 11: ...tion of the burner controls Br brown Gr green Bk black Blue blue Or orange Pur purple Gray gray Wire color coding 120 factory wiring VAC 24 factory wiring VAC 120 field wiring VAC 24 field wiring VAC...

Страница 12: ...e plate clockwise to the closed position 3 Check the air throttle indicator The 0 position of the indicator should be even with the end of the air inlet tube If not bend the arm slightly until the ind...

Страница 13: ...n Gas valve on light remains on during normal running indicating gas valve is energized Shutdown When the call for heat ends the primary control immediately deactivates the gas valve and blower The bu...

Страница 14: ...for combination gas valve outlet pressure Adjust valve regulator if necessary so the reading is 3 5 inches w c for either natural gas or propane gas Inspect flame Look at flame through appliance obser...

Страница 15: ...from the combustion chamber If CO2 is noticeably lower overfire than in the vent the appliance has leaks that must be repaired 5 Perform Checkout Procedures Fill Out Certificate continued Check flame...

Страница 16: ...of barometric damper and spill switch If the building contains any exhaust fans or conditions that could affect vent performance check burner appliance vent operation with exhaust fans or other condit...

Страница 17: ...ur 8 32 screws securing the air tube back plate 6 Maintenance and Service Procedures 7 Swing the hold on bracket away and carefully pull out the ignition tube assembly As the white ceramic is exposed...

Страница 18: ...housing cover 6 Maintenance and Service Procedures continued Replacing blower motor or wheel Follow this procedure to replace motor or wheel 1 Remove the four 8 32 screws in the motor mounting plate...

Страница 19: ...nnect the motor leads and power the motor directly with 120 V to check motor operation Bad primary control If all above tests prove negative replace control Burner pre purges for 34 seconds but does n...

Страница 20: ...hrottle according to desired input Wrong orifice size Check orifice drill size Manifold pressure Adjust regulator to 3 5 W C for natural gas or propane Inadequate gas supply Line pressure requirements...

Страница 21: ...ative overfire pressure The G3B burner must not be installed on a product that operates with a pressurized combustion chamber Failure to comply could result in severe personal injury death or substant...

Страница 22: ...in 54858 13 Insulator Tube 2 required 74617 14 Hot Surface Ignitor NORTON 120 volt 5 3 8 OAL 87197S 15 Gasket ignitor assembly 40360 16 Rear Ignitor Assembly 6 overall length 7 1 2 9 overall length 10...

Страница 23: ...Model G3B Gas burner Instruction manual MNG3B Gas 041015 23 9 Replacement parts continued...

Страница 24: ...Model G3B Gas burner Instruction manual MNG3B Gas 041015 24...

Отзывы: