Technical data
Vario II series
16
Operating manual
12.11
3.1 Control inputs and outputs (option I)
Via signal outputs various operating modes of the printer can be
demanded.
The signal outputs are made available vial two 9-pin D-Sub-sockets
(Output 1) at the rear of the Control Unit. They consist of opto-
integrator semiconductor lines which are switched through res.
blocked out corresponding to the different operating modes.
In case a control output is active, then the corresponding output is to
strain with a maximum current of 30mA.
Figure 2
PIN
(socket)
Output I
Out 1: Error message
Each error status such as ribbon error is displayed.
Out 2: Print order
The printer was activated with a print order. Now print
start by IN1 is possible.
Out 3: Label generation
The printer is filled with current label data.
In case in dispensing mode either dispensing photocell
or dispensing photocell continuous is selected it is
indicated if a label is under photocell and ready to pick
up.
Out 4: Single print
The contents of printer memory is printed to the
corresponding medium by printhead.
Control outputs