Technical Data
DPM III xi series
18
Operating manual
04.18
4.1 Control Inputs and Outputs (Standard)
Figure 5
A = External output 1-4 (Output I)
B = External input 1-4 (Input I)
C = External output 5-8 (Output II)
D = External bushing 15pin (I/O-24)
By means of the signal outputs different operating states of the print
module can be queried.
The signal outputs are provided by two 9-pin SUB-D-bushings
(OUTPUT I and OUTPUT II) on the back side of the control unit.
They consist of optocoupler semiconductor sections, which are
connected through and/or blocked according to different operating
states.
The maximum allowable current in a semiconductor section is
lmax = 30 mA.
Output I
Figure 5, A
Figure 6
PIN (bushing)
Output I
Out 1: Error message
Each error status such as ribbon
error is displayed.
Out 2: Print order
The print module was activated by a
print order.
Out 3: Generation
The print module is filled with current
layout data.
Out 4: Layout print
The content of print memory is
transferred on the printable medium
by means of the printhead.
Plug connection - back
side of control unit
Control outputs
Содержание DPM III XI
Страница 1: ......
Страница 8: ......
Страница 22: ...Technical Data DPM III xi series 22 Operating manual 04 18 Example 1 Example 2 Example 3 ...
Страница 34: ......
Страница 38: ......
Страница 62: ......
Страница 72: ...Signal Diagrams DPM III xi series 72 Operating manual 04 18 10 2 Mode 2 continuous mode ...
Страница 84: ......
Страница 90: ......
Страница 92: ......
Страница 95: ......
Страница 96: ......